RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
458
Nov 29, 2019
Caution
When using the SNOOZE mode while SSECm is set to 1, no overrun errors occur. Therefore,
when using the SNOOZE mode, read bits 7 to 0 (RxDq) of the SDRm1 register before switching to
the STOP mode.
Remarks 1.
<1> to <9> in the figure correspond to <1> to <9> in
Figure 11-117 Timing Chart of SNOOZE
Mode Operation (Abnormal Operation <2>)
.
2.
m = 0; q = 0