RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
347
Nov 29, 2019
Figure 11-29. Flowchart of Master Transmission (in Single-Transmission Mode)
Starting CSI communication
Write STmn bit to 1
Transmission completed?
No
Yes
End of communication
Writing transmit data to
SIOp (=SDRmn[7:0])
When Transfer end interrupt is generated, it
moves to interrupt processing routine
Setting transmit data
For the initial setting, see
Figure 11-25
.
(Select Transfer end interrupt)
SAU default setting
Wait for transmit completes
Transfer end interrupt
Enables interrupt
Clear interrupt request flag (XXIF), reset interrupt mask (XXMK) and set
interrupt enable (EI).
Disable interrupt (MASK)
Set data for transmission and the number of data. Clear communication end flag
(Storage area, Transmission data pointer, Number of communication data and
Communication end flag are optionally set on the internal RAM by the software)
Check completion of transmission by
verifying transmit end flag
Writing to SIOp makes SOp and
SCKp signals out
(communication starts)
Read transmit data from storage area and write it
to SIOp. Update transmit data pointer.
Read transmit data, if any, from storage area and
write it to SIOp. Update transmit data pointer.
If not, set transmit end flag
Ma
in ro
ut
in
e
Ma
in r
ou
tin
e
In
te
rr
upt
p
ro
c
essing
ro
ut
ine
Transmitting next data?
Writing transmit data to
SIOp (=SDRmn[7:0])
No
Sets communication
completion flag
RETI
Yes