RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
399
Nov 29, 2019
11.6 Clock Synchronous Serial Communication with Slave Select Input Function
Channel 0 of SAU0 correspond to the clock synchronous serial communication with slave select input function.
[Data transmission/reception]
Data length of 7 or 8 bits
Phase control of transmit/receive data
MSB/LSB first selectable
Level setting of transmit/receive data
[Clock control]
Phase control of I/O clock
Setting of transfer period by prescaler and internal counter of each channel
Maximum transfer rate
Note
During slave communication: Max. f
MCK
/6
[Interrupt function]
Transfer end interrupt/buffer empty interrupt
[Error detection flag]
Overrun error
[Expansion function]
• Slave select function
Note
Use this operation within a range that satisfies the conditions above and the AC characteristics in the
electrical specifications (see
CHAPTER 27 ELECTRICAL SPECIFICATIONS
).
Unit
Channel
Used as CSI
Used as UART
0 0
CSI00 (supporting slave
select input function)
UART0
1
Slave select input function performs the following three types of communication operations.
Slave transmission
(See
11.6.1
.)
Slave reception
(See
11.6.2
.)
Slave transmission/reception
(See
11.6.3
.)