CHAPTER 20 SAFETY FUNCTIONS
R01UH0895EJ0100 Rev.1.00
659
Nov 29, 2019
20.10.1 A/D test register (ADTES)
This register is used to select the A/D converter’s positive reference voltage, the A/D converter’s negative reference
voltage, or the analog input channel (ANIxx), temperature sensor output voltage, or internal reference voltage (1.45 V) as
the target of A/D conversion.
When using the A/D test function, specify the following settings:
Select AV
REFM
as the target of A/D conversion when converting the internal 0 V.
Select AV
REFP
as the target of A/D conversion when converting AV
REF
.
The ADTES register can be set by an 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
Figure 20-16. Format of A/D Test Register (ADTES)
Address: F0013H After reset: 00H R/W
Symbol
7 6 5 4 3 2 1 0
ADTES
0 0 0 0 0 0
ADTES1
ADTES0
ADTES1
ADTES0
A/D conversion target
0
0
ANIxx/temperature sensor output
Note
/internal reference voltage (1.45 V)
Note
(This is specified using the analog input channel specification register (ADS).)
1 0
AV
REFM
1 1
AV
REFP
Other than above
Setting prohibited
Note
Temperature sensor output/internal reference voltage (1.45 V) can be used only in HS (high-speed
main) mode.