RL78/G1P
CHAPTER 19 VOLTAGE DETECTOR
R01UH0895EJ0100 Rev.1.00
629
Nov 29, 2019
19.3.2 Voltage detection level register (LVIS)
This register selects the voltage detection level.
This register can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation input sets this register to 00H/01H/81H
Note 1
.
Figure 19-3. Format of Voltage Detection Level Select Register (LVIS)
Address: FFFAAH After reset: 00H/01H/81H
Note 1
R/W
Symbol
<7>
6 5 4 3 2 1
<0>
LVIS
LVIMD
0 0 0 0 0 0
LVILV
LVIMD
Note 2
Operation mode of voltage detection
0
Interrupt
mode
1
Reset
mode
LVILV
Note 2
LVD detection level
0
High-voltage detection level (V
LVDH
)
1
Low-voltage detection level (V
LVDL
or V
LVDL
)
Notes 1.
The reset value changes depending on the reset source and the setting of the option byte.
This register is not cleared (00H) by LVD reset.
The generation of reset signal other than an LVD reset sets as follows.
When option byte LVIMDS1, LVIMDS0 = 1, 0: 00H
When option byte LVIMDS1, LVIMDS0 = 1, 1: 81H
When option byte LVIMDS1, LVIMDS0 = 0, 1: 01H
2.
Writing “0” can only be allowed when LVIMDS1 and LVIMDS0 are set to 1 and 0 (interrupt and reset
mode) by the option byte. In other cases, writing is not allowed and the value is switched automatically
when reset or interrupt is generated.
Cautions 1. Only rewrite the value of the LVIS register after setting the LVISEN bit (bit 7 of the LVIM register)
to 1.
2. Specify the LVD operation mode and detection voltage (V
LVDH
, V
LVDL
, V
LVD
) by using the option
byte (000C1H). Table 19-1 shows the option byte (000C1H) settings. For details about the
option byte, see CHAPTER 22 OPTION BYTE.