CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
353
Nov 29, 2019
Figure 11-34. Procedure for Stopping Master Reception
Starting setting to stop
Stop setting is completed
Write 1 to the STmn bit of the target channel.
(SEmn = 0: to operation stop status)
The master transmission is stopped.
Go to the next processing.
Set the SOEmn bit to 0 and stop the output of
the target channel.
Writing the STm register
Changing setting of the SOEm register
TSFmn = 0?
If there is any data being transferred, wait for
their completion.
(If there is an urgent must stop, do not wait)
Yes
No
The levels of the serial clock (CKOmn) and
serial data (SOmn) on the target channel can
be changed if necessitated by an emergency.
Reset the serial array unit by stopping the
clock supply to it.
Changing setting of the SOm register
Setting the PER0 register
(Essential)
(Selective)
(Essential)
(Selective)
(Selective)