Page 42 of 98
7.3.2
Camera pointing up
In this mode, a product is placed on top of the
device's base plate and the product is moved into the
measurement field. Since ambient light will affect the
measurement, the measurement area must be
covered so as to protect it from ambient light. In this
scenario, the REA MLV-2D uses the terminal as its
base. The blue rubber rings on the terminal protect
the keyboard and display from damage, since they do
not touch the supporting surface.
7.3.3
Camera pointing sideways
The device is laid on its side as shown in the figure or is placed in the measurement
desk support. The codes to be measured are located on cans, bottles or parts (for
example) that can be positioned in front of the device to ensure that measurement
conditions are correctly maintained.
Figure: Device on its side with product in front of the device