background image

Quick Start Guide

General View

 

 

 

1

2

5

6

7

4

3

1 = Laser Beam Output Window
2 = POWER ON LED
3 = Warning and Device Class Labels
4 = Accessory Mounting Holes
5 = Mounting Holes
6 = LEDs
7 = Push Button

NOTE:

The Quick Start Guide describes stand-alone application. For other types of installations, such as ID-

NET

, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using

GeniusPlus configuration program, refer to the TCNM-AD/EX Manual.

STEP 1 – Connect the System

NOTE: This section illustrates a standalone application. For a pass-through installation, refer to the

appropriate section. For complete scanner configuration using the GeniusPlus configuration program,

refer to the Context-Sensitive Help On-Line.

To connect the system in a standalone configuration, you need the hardware indicated below. In this layout, the data is

transmitted to the Host on the main serial interface.

In Local Echo communication mode, data is transmitted on the RS-232 auxiliary interface independently from the

main interface selection.

When On Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when

the object enters its reading zone.

TCNM-AD Barcode Scanner

 

 

P/N 175718 Rev. A

29 January 2014

0 175718

7

Содержание TCNM-AD

Страница 1: ...plication For a pass through installation refer to the appropriate section For complete scanner configuration using the GeniusPlus configuration program refer to the Context Sensitive Help On Line To connect the system in a standalone configuration you need the hardware indicated below In this layout the data is transmitted to the Host on the main serial interface In Local Echo communication mode ...

Страница 2: ...nd O1 Output 1 O1 Output 1 Inputs O2 Output 2 V Power Source External Trigger O2 Output 2 I1A External Trigger A polarity insensitive Auxiliary Interface I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference I2A Input 2 A polarity insensitive ID NET I2B Input 2 B po...

Страница 3: ...pin connector 13 25 14 1 Figure 2 25 pin male D sub connector 25 pin D sub male connector pinout Pin Name Function 13 9 Vdc Power supply input voltage 25 7 GND Power supply input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A polarity insensitive 10 I2B Input 2 B polarity insensitive ...

Страница 4: ...ew Tilt Skew Pitch Figure 3 Positioning with mounting bracket 2 When mounting the barcode scanner take into consideration these three ideal label position angles Skew 10 to 30 Tilt 0 and Pitch 0 Ensure at least 10 Minimize Tilt Angle Minimize Pitch Angle S T P Skew Angle Figure 4 Skew Tilt and Pitch Angles 3 Refer to the Reading Diagrams to determine the distance at which your scanner should be po...

Страница 5: ...ce the Oscillating Mirror remains in the default fixed position 15 to make barcode reading easier while performing the SMART TEACH functions Table 1 Indicators Label Color Meaning READY Green Indicates the device is ready to operate GOOD Green Confirms successful reading TRIGGER Yellow Indicates the status of the reading phase COM Yellow Indicates active communication on main serial port STATUS Re...

Страница 6: ...the end of the Auto Learn procedure you may follow the Auto Setup procedure to set up the reading parameters 1 Hold the SMART TEACH push button pressed until the SETUP LED is on 2 Release the button to enter the Auto Setup function 3 Once entered if a barcode label is positioned in front of the scanline the scanner automatically performs the optimal setup of the reading parameters for that specifi...

Страница 7: ...assumes scanner connection to a TCNM ACBB1 GeniusPlus running on a laptop computer is connected to the scanner auxiliary port through the TCNM ACBB1 9 pin connector To communicate with the scanner GeniusPlus performs an auto baud rate detection starting from its default parameters which are 115200 8 N 1 These parameters can also be set in the GeniusPlus Tools Options Communications window Wizard f...

Страница 8: ...r When working in this mode the reader is continuously scanning while the reading phase is activated each time a barcode enters the reader reading zone The reader stops reading after an N number of scans without a code Barcode characters are transmitted on the serial interface In case of a failed reading phase no message is sent to the host computer c Configure one or both digital outputs by selec...

Страница 9: ...fining the parameter values the following window appears allowing you to complete the reader configuration as follows Save the configuration to disk Switch to Advanced Mode Send the configuration to the scanner TCNM AD Barcode Scanner P N 175718 Rev A www bannerengineering com tel 763 544 3164 9 ...

Страница 10: ... 1 To enter Test Mode hold down the SMART TEACH push button until the TEST LED is on 2 Once entered the bar graph on the five LEDs is activated and if the scanner starts reading barcodes the bar graph shows the Good Read Rate In case of no read condition only the STATUS LED is on and blinking SETUP LEARN TEST READY GOOD TRIGGER COM STATUS green green yellow yellow red TCNM AD Barcode Scanner 10 ww...

Страница 11: ...m a host computer using the Host Mode programming procedure and commands via the serial interface See the Host Mode Programming file on the CD Alternative Layouts The ID NET network is a built in speed interface dedicated for high speed scanner interconnection ID NET is in addition to the Main and Auxiliary serial interfaces If you need an ID NET network refer to the TCNM AD EX manual The scanner ...

Страница 12: ...ndard Resolution TCNM AD 2200 High Resolution TCNM AD 1204 Standard Resolution TCNM AD 2204 High Resolution Note 0 0 is the center of the laser beam output window TCNM AD Barcode Scanner 12 www bannerengineering com tel 763 544 3164 P N 175718 Rev A ...

Страница 13: ...0 40 mm 1 6 in 300 mm 11 8 in on 0 50 mm 20 mils codes 12X4 50 mm 1 8 in 310 mm 11 8 in on 0 50 mm 20 mils codes 22X0 30 mm 1 2 in 90 mm 3 5 in on 0 30 mm 12 mils codes 22X4 30 mm 1 2 in 90 mm 3 5 in on 0 30 mm 12 mils codes Refer to the diagrams given in Reading Diagrams for further details on the reading features They are taken on various resolution sample codes at a 25 C ambient temperature dep...

Страница 14: ...sistance N 60068 2 29 30g 6 ms 5000 shocks on each axis Environmental Rating IP65 Protection Class EN 60529 Dimensions 68 x 84 x 34 mm 2 7 x 3 3 x 1 3 in Weight 330 g 11 6 oz LED Indicators Ready Good Trigger Com Status Power On Multi function Key SMART TEACH button Software Readable Codes EAN UPC including Add on 2 and Add on 5 7 2 5 Interleaved7 ABC Codabar Codabar7 Code 39 Standard and Full ASC...

Страница 15: ...acket and may be used for installation 23 3 0 92 14 0 55 84 3 31 4 0 16 10 3 0 41 40 1 57 0 41 10 3 40 1 57 14 7 0 58 M 4 n 4 1 29 32 7 mm inch 68 2 68 46 1 81 The quote refers to the scan line Figure 5 Overall Dimensions 9 4 2 7 8 20 2 5 73 42 R 4 0 4 2 90 30 13 8 17 5 2 5 23 units in mm 4 2 n 2 1 x 45 n 2 Figure 6 Mounting Bracket Overall Dimensions 7 ACR Readable TCNM AD Barcode Scanner P N 175...

Страница 16: ...ight and the device classification are applied onto the body of the scanner Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product according to CDRH regulations Any violation of...

Страница 17: ...precision product and it must be handled correctly before and during installation to avoid damage Avoid that the scanners hit one another causing damage They should be handled separately Avoid that the scanners are dropped exceeding shock limits Do not fine tune the positioning by striking the scanner or bracket Do not weld the scanner into position this can cause electrostatic heat or output wind...

Отзывы: