background image

Specifications

Sensor

Input Power

Supply Voltage: 10–30V dc
Power consumption: Maximum 0.5 to 0.17 A; 5 W

Serial Interfaces

Main Serial Interface: Sw programmable: RS232;

RS485 FD and HD
Baud rate: 1200 to 115200
Auxiliary: RS232
Baud rate: 1200 to 115200
ID-NET

: RS485 Half-duplex

Baud rate: Up to 1 MBaud

Inputs

Input 1 (External Trigger), Input 2: Optocoupled,

polarity insensitive
Voltage: 10–30V dc
Current Consumption: 12 mA maximum
Minimum Pulse Duration: 5 ms

Outputs

Output 1, Output 2: Optocoupled
V

CE

: 30V dc maximum

Collector Current: 40 mA continuous maximum; 130

mA pulsed maximum
V

CE saturation

: 1V maximum at 10 mA

Power Dissipation: 80 mW maximum at 45 °C

(ambient temperature)

Optical Features

Light Source: Semiconductor laser diode
Wave Length: 630 to 680 nm
Safety Class: Class 2 - EN 60825-1; CDRH

Reading Features

5

Scan Rate (software): (600 to 1000 scans/sec)
Aperture Angle: 50°
Maximum Reading Distance and Resolution: see 

Reading Performance (TCNM-EX Models)

 and 

Reading

Performance (TCNM-AD Models)

 on page 13

Operating Conditions

Operating Temperature

6

: 0 °C to +45 °C (+32 °F to

+113 °F)
Storage Temperature: 

20 °C to +70 °C (

4 °F to

+158 °F)
Humidity: 90% (non-condensing)
Vibration Resistance EN 60068-2-6: 14 mm at 2 to 10

Hz; 1.5 mm at 13 to 55 Hz; 2 g at 70 to 200 Hz; 2

hours on each axis
Bump Resistance N 60068-2-29: 30g; 6 ms; 5000

shocks on each axis

Environmental Rating

IP65
Protection Class – EN 60529

Dimensions

68 x 84 x 34 mm (2.7 x 3.3 x 1.3 in)

Weight

330 g (11.6 oz)

LED Indicators

Ready, Good, Trigger, Com, Status, Power On

Multi-function Key

SMART-TEACH button

Software

Readable Codes

EAN/UPC (including Add-on 2 and Add-on 5)

7

2/5 Interleaved

7

ABC Codabar
Codabar

7

Code 39 (Standard and Full ASCII)

7

Code 93

7

Code 128

7

EAN 128

7

GS1 DataBar

7

GS1 DataBar Expanded

7

GS1 DataBar Limited
ISBT 128
Pharmacode
Plessey

Code Selection

Up to ten different symbologies during one reading

phase

Decoding Safety

Can enable multiple good reads of same code

Headers and Terminators

Up to 128-byte header string
Up to 128-byte terminator string

Operating Modes

On Line, Serial On Line, Verifier, Automatic,

Continuous, Test

Configuration Modes

SMART-TEACH Functions
GeniusPlus utility program
GeniusPlus based Host Mode Programming

Special Functions

Code Verifier
Advanced Code Reconstruction
Motor Off and SW_Speed Control
Programmable Diagnostic and Statistic Messages

Parameter Storage

Non-volatile internal Flash

5 Further details given in the Reader Performance tables.

6 If the reader is used in high temperature environments (over 40° C), use of the Beam Shutter is advised (see the GeniusPlus configuration program) and/or

a thermally conductive support (such as the metal bracket provided).

 

 

TCNM-AD Barcode Scanner

14

www.bannerengineering.com - tel: 763-544-3164

P/N 175718 Rev. A

Содержание TCNM-AD

Страница 1: ...plication For a pass through installation refer to the appropriate section For complete scanner configuration using the GeniusPlus configuration program refer to the Context Sensitive Help On Line To connect the system in a standalone configuration you need the hardware indicated below In this layout the data is transmitted to the Host on the main serial interface In Local Echo communication mode ...

Страница 2: ...nd O1 Output 1 O1 Output 1 Inputs O2 Output 2 V Power Source External Trigger O2 Output 2 I1A External Trigger A polarity insensitive Auxiliary Interface I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference I2A Input 2 A polarity insensitive ID NET I2B Input 2 B po...

Страница 3: ...pin connector 13 25 14 1 Figure 2 25 pin male D sub connector 25 pin D sub male connector pinout Pin Name Function 13 9 Vdc Power supply input voltage 25 7 GND Power supply input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A polarity insensitive 10 I2B Input 2 B polarity insensitive ...

Страница 4: ...ew Tilt Skew Pitch Figure 3 Positioning with mounting bracket 2 When mounting the barcode scanner take into consideration these three ideal label position angles Skew 10 to 30 Tilt 0 and Pitch 0 Ensure at least 10 Minimize Tilt Angle Minimize Pitch Angle S T P Skew Angle Figure 4 Skew Tilt and Pitch Angles 3 Refer to the Reading Diagrams to determine the distance at which your scanner should be po...

Страница 5: ...ce the Oscillating Mirror remains in the default fixed position 15 to make barcode reading easier while performing the SMART TEACH functions Table 1 Indicators Label Color Meaning READY Green Indicates the device is ready to operate GOOD Green Confirms successful reading TRIGGER Yellow Indicates the status of the reading phase COM Yellow Indicates active communication on main serial port STATUS Re...

Страница 6: ...the end of the Auto Learn procedure you may follow the Auto Setup procedure to set up the reading parameters 1 Hold the SMART TEACH push button pressed until the SETUP LED is on 2 Release the button to enter the Auto Setup function 3 Once entered if a barcode label is positioned in front of the scanline the scanner automatically performs the optimal setup of the reading parameters for that specifi...

Страница 7: ...assumes scanner connection to a TCNM ACBB1 GeniusPlus running on a laptop computer is connected to the scanner auxiliary port through the TCNM ACBB1 9 pin connector To communicate with the scanner GeniusPlus performs an auto baud rate detection starting from its default parameters which are 115200 8 N 1 These parameters can also be set in the GeniusPlus Tools Options Communications window Wizard f...

Страница 8: ...r When working in this mode the reader is continuously scanning while the reading phase is activated each time a barcode enters the reader reading zone The reader stops reading after an N number of scans without a code Barcode characters are transmitted on the serial interface In case of a failed reading phase no message is sent to the host computer c Configure one or both digital outputs by selec...

Страница 9: ...fining the parameter values the following window appears allowing you to complete the reader configuration as follows Save the configuration to disk Switch to Advanced Mode Send the configuration to the scanner TCNM AD Barcode Scanner P N 175718 Rev A www bannerengineering com tel 763 544 3164 9 ...

Страница 10: ... 1 To enter Test Mode hold down the SMART TEACH push button until the TEST LED is on 2 Once entered the bar graph on the five LEDs is activated and if the scanner starts reading barcodes the bar graph shows the Good Read Rate In case of no read condition only the STATUS LED is on and blinking SETUP LEARN TEST READY GOOD TRIGGER COM STATUS green green yellow yellow red TCNM AD Barcode Scanner 10 ww...

Страница 11: ...m a host computer using the Host Mode programming procedure and commands via the serial interface See the Host Mode Programming file on the CD Alternative Layouts The ID NET network is a built in speed interface dedicated for high speed scanner interconnection ID NET is in addition to the Main and Auxiliary serial interfaces If you need an ID NET network refer to the TCNM AD EX manual The scanner ...

Страница 12: ...ndard Resolution TCNM AD 2200 High Resolution TCNM AD 1204 Standard Resolution TCNM AD 2204 High Resolution Note 0 0 is the center of the laser beam output window TCNM AD Barcode Scanner 12 www bannerengineering com tel 763 544 3164 P N 175718 Rev A ...

Страница 13: ...0 40 mm 1 6 in 300 mm 11 8 in on 0 50 mm 20 mils codes 12X4 50 mm 1 8 in 310 mm 11 8 in on 0 50 mm 20 mils codes 22X0 30 mm 1 2 in 90 mm 3 5 in on 0 30 mm 12 mils codes 22X4 30 mm 1 2 in 90 mm 3 5 in on 0 30 mm 12 mils codes Refer to the diagrams given in Reading Diagrams for further details on the reading features They are taken on various resolution sample codes at a 25 C ambient temperature dep...

Страница 14: ...sistance N 60068 2 29 30g 6 ms 5000 shocks on each axis Environmental Rating IP65 Protection Class EN 60529 Dimensions 68 x 84 x 34 mm 2 7 x 3 3 x 1 3 in Weight 330 g 11 6 oz LED Indicators Ready Good Trigger Com Status Power On Multi function Key SMART TEACH button Software Readable Codes EAN UPC including Add on 2 and Add on 5 7 2 5 Interleaved7 ABC Codabar Codabar7 Code 39 Standard and Full ASC...

Страница 15: ...acket and may be used for installation 23 3 0 92 14 0 55 84 3 31 4 0 16 10 3 0 41 40 1 57 0 41 10 3 40 1 57 14 7 0 58 M 4 n 4 1 29 32 7 mm inch 68 2 68 46 1 81 The quote refers to the scan line Figure 5 Overall Dimensions 9 4 2 7 8 20 2 5 73 42 R 4 0 4 2 90 30 13 8 17 5 2 5 23 units in mm 4 2 n 2 1 x 45 n 2 Figure 6 Mounting Bracket Overall Dimensions 7 ACR Readable TCNM AD Barcode Scanner P N 175...

Страница 16: ...ight and the device classification are applied onto the body of the scanner Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product according to CDRH regulations Any violation of...

Страница 17: ...precision product and it must be handled correctly before and during installation to avoid damage Avoid that the scanners hit one another causing damage They should be handled separately Avoid that the scanners are dropped exceeding shock limits Do not fine tune the positioning by striking the scanner or bracket Do not weld the scanner into position this can cause electrostatic heat or output wind...

Отзывы: