REA
VERIFIER
© REA Elektronik GmbH, 64367 Mühltal, Germany --- REA MLV-2D Manual Version 3 – 21/12/2015
Page 61 of 98
Example of a verification report (long text format)
TransWin32, Version 1.0.16.1/11490r
F. Verweyen
VRF, REA Elektronik GmbH
Teichwiesenstrasse 1, Mühltal-Waschenbach Deutschland-Germany
Comment: Manual Documentation
Operator:
Verweyen
Job number:
Test job 47
11
Aperture:
14 mil, 0.356 mm
Light source:
660nm / 45° Q
Lens:
Pentax 35 mm
Unit:
Micrometer [µm]
Date:
02/22/
2012 10:22:19 AM
Device:
REA MLV-2D (V.1.0.16.0/11492r)
Serial number:
0030.025.100-00532-9
Verifier:
Software V.1.0.16.0/11497r
Reflectance adjustment: 02/18/2012, Valid until 03/19/2012
Level Correction:
02/18/2012, Valid until 03/19/2012
Scale adjustment:
02/18/2012, Valid until 03/19/2012
Symbology:
GS1 Data Matrix ECC200
Code content (HR)
(01)01234567890123(21)12345678901234
(17)050309(10)A123456x
Data structure (GS1)
1) 01
AI
2) 0123456789012
GTIN
3)
3
Check digit
Invalid Check digit in field,actual : 3, nominal : 8
3) 21
AI
4) 12345678901234
SERIAL
5) [GS]
Field separator
6) 17
AI
7) 050309
USE BY / EXPIRY
8) 10
AI
9) A123456x
BATCH/LOT
Data structure:
Fail
0
User comment:
This is a test comment
Evaluation: ISO/IEC 15415, ISO/IEC 16022, GS1 General Specifications
Symbol:
Fail 0.0/14/625/45° Q
Error list:
01) Data structure analysis failed
02) The modulation value is too low