10.10 Storing sample stages and cell bodies
Once a sample stage has been removed from a cell body, it should be stored in the membrane con-
tainer in which it shipped. Various stages and cell bodies are shown below, stored in their con-
tainers.
Heater stage
Gas cell body
Passive stage
Tip:
For cell bodies we recommend storing the membrane clamping ring attached to the cell
body with its eight screws and placing any other associated accessories such as cables with the
cell in the box.
10.10.1 Storing sample stage and cell body combinations
Since cell bodies must always be used while attached to a sample stage, we recommend storing
them together when possible. For this purpose the cell body is shipped in a somewhat larger con-
tainer and includes a plastic cap which is used when storing cell bodies and samples stages
together in the box. The following procedure describes their use.
1. Locate the box.
l
Locate the cell body storage container.
l
It should include the storage cup.
2. Place the assembly.
l
Open the box and remove the cup.
l
Place the sample stage / cell body as shown. In this
example it is a gas cell and heater stage combination.
Page 91 of 243
10 Cell Body and Sample Stage Guide
Содержание Cypher SPM
Страница 1: ...Cypher SPM User Guide Part No XX XXXX XXX...
Страница 8: ...Part I Getting Started System safety and overview...
Страница 165: ...Cypher SPM User Guide Sub Figure a First view of new cantilever 24 Engaging the cantilever on the sample Page 165 of 243...
Страница 167: ...Cypher SPM User Guide Sub Figure c Cantilever in focus See 9 24 Engaging the cantilever on the sample Page 167 of 243...
Страница 169: ...Cypher SPM User Guide Sub Figure a Cantilever Zoom See 10 24 Engaging the cantilever on the sample Page 169 of 243...
Страница 170: ...Cypher SPM User Guide Sub Figure b Laser Spot ON See 11 Page 170 of 243 24 Engaging the cantilever on the sample...
Страница 173: ...Cypher SPM User Guide Sub Figure a Offset 24 Engaging the cantilever on the sample Page 173 of 243...
Страница 176: ...Cypher SPM User Guide Sub Figure a Master Panel Main Tab Page 176 of 243 24 Engaging the cantilever on the sample...
Страница 186: ...Cypher SPM User Guide Sub Figure a Before the Move Page 186 of 243 25 AC mode imaging...
Страница 189: ...Cypher SPM User Guide 26 26 Contact Mode Imaging In Air 26 Contact mode imaging in air Page 189 of 243...
Страница 216: ...Part VI Shipping and Maintenance This part of the user guide covers moving and shipping the instrument...