Master Channel Panel
(Ctrl + 7) During imaging, multiple data streams, such as height, cantilever amplitude and phase,
return from the AFM to the computer. This panel contains information about those data streams
and allows for some real time scaling and processing.
Igor Command Window
(Ctrl + J) Not shown. The Igor Command window has two parts: the history and the command line.
On occasion items executed by clicking software buttons will generate output and print it to the his-
tory. It is not a bad idea to keep tabs on what is being printed into the history, especially if you are
tracking down software bugs. Advanced users will use the command line to directly execute a vari-
ety of tasks. If you followed the Igor tutorial recommended in the Tip on page
you will
know how to use the command line. The Igor Command Window always has the name of your cur-
rent experiment, which you can also see at the top of the border of the software window.
Sum and Deflection Meter
(Ctrl + 6) This is a real time display of various channels such as cantilever sum and deflection, piezo
voltage, amplitude, and phase.
Engage Panel
(Ctrl + 8) This panel controls the entire process of the cantilever approach to the sample. Its three
tabs control:
Approach
Motorized approach of cantilever and microscope objective toward the sample.
Detector
Centering of reflected light beam (laser or SLD) onto the optical detector.
Prefs
Preferences for the engage process such as approach speed and approach step size.
Real Time Image Display
This is an example of an image window, in this case displaying the individual lines of the sample
topography as the cantilever moves left to right over the sample. There is usually one such window
per active tab in the Master Channel Panel (Lower left hand window). The amplitude and phase
data windows are to the right of this clipped screen shot. While this panel is primarily a data dis-
play, right clicking with the mouse can activate various commands such as Zoom and Translate.
The white area at the bottom of this window shows a real time oscilloscope view of the most recent
line of image data.
Scope Graph
This oscilloscope view shows a graph of the most current scan line. Both trace and retrace can be
selected on the Master Channel Panel.
1. Q Oops! I accidentally closed one of the control panel windows. How do I get
it back?
2. A You can reactivate the panels via AFM Controls in the top menu bar.
A few other things of note are:
Menu Bar
4 What is a Cypher SPM system?
Page 28 of 243
Содержание Cypher SPM
Страница 1: ...Cypher SPM User Guide Part No XX XXXX XXX...
Страница 8: ...Part I Getting Started System safety and overview...
Страница 165: ...Cypher SPM User Guide Sub Figure a First view of new cantilever 24 Engaging the cantilever on the sample Page 165 of 243...
Страница 167: ...Cypher SPM User Guide Sub Figure c Cantilever in focus See 9 24 Engaging the cantilever on the sample Page 167 of 243...
Страница 169: ...Cypher SPM User Guide Sub Figure a Cantilever Zoom See 10 24 Engaging the cantilever on the sample Page 169 of 243...
Страница 170: ...Cypher SPM User Guide Sub Figure b Laser Spot ON See 11 Page 170 of 243 24 Engaging the cantilever on the sample...
Страница 173: ...Cypher SPM User Guide Sub Figure a Offset 24 Engaging the cantilever on the sample Page 173 of 243...
Страница 176: ...Cypher SPM User Guide Sub Figure a Master Panel Main Tab Page 176 of 243 24 Engaging the cantilever on the sample...
Страница 186: ...Cypher SPM User Guide Sub Figure a Before the Move Page 186 of 243 25 AC mode imaging...
Страница 189: ...Cypher SPM User Guide 26 26 Contact Mode Imaging In Air 26 Contact mode imaging in air Page 189 of 243...
Страница 216: ...Part VI Shipping and Maintenance This part of the user guide covers moving and shipping the instrument...