14.4
Embodiment DIO: 3 Digital Outputs and 2 Digital I/Os
Assignment D-Sub Connector Embodiment DIO
Pin Assignment
1
Shield (The shield must be connected at both cable ends to the respective
device housing.)
6
Ground (0V)
2
Power Supply (+24V)
4
Common switching voltage for optocoupler outputs and optocoupler I/Os
(Pins 3, 5, 7, 8 und 9)
8
Output 3
Optocoupler outputs
Positive polarity:
When active, the transistor is conductive
Negative polarity:
When active, the transistor is not conducting
7
Output 2
3
Output 1
(Monitoring 2)
9
I/O 1 (Bit 2
0
)
Bidirectional optocoupler inputs/outputs (I/Os)
5
I/O 2 (Bit 2
1
)
Warning
If the bidirectional optocoupler inputs/outputs at pin 5 and pin 9 are used as inputs, it must be ensured that
the voltage at these pins is never higher than the voltage at pin 4! If the voltage is higher, the in the LVMC
integrated hardware protection circuit will be activated, which may damage externally connected compo-
nents!