Interface A2, Release Date: 02.03.2022
Page 62
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
Captured sensor images can be stored on a data storage medium. Either this is done manually for the cur-
rently displayed sensor image via the menu item “Save Current Sensor Image to File” in the “File” menu, or
automatically in real time with the maximum possible speed. If automatic storing is activated, images will be
lost if objects follow each other faster than the files can be stored on the data storage medium. On the anal-
ysis page, the number of captured images and the number of stored images are displayed, so that it can be
determined whether all files could be created.
5.12.2
Section “Last Object”
The “Last Object” section displays information about the last detected object. The displayed values are
cleared when the LVMC is restarted (by switching power on or by pressing one of the „Reboot LVMC“ or
„Start“ buttons), or when the analysis is reset (by pressing the „Reset Analysis“ button).
Explanation of the shown values:
“Minimum Size”:
The minimum size of the last object detected, when 15 percent of the beginning and of
the end of the object are cut-off.
“Maximum Size”: The maximum size of the last object detected.
“Passing Time”:
The passing time of the last object detected.
“Area”:
The area of the last object detected in time multiplied by length.
“Date”:
The date when the last object was detected.
“Time”:
The point in time when the last object was detected.
5.12.3
Section “All Objects”
In the section “All Objects”, statistical data on the detected objects are available. The displayed values are
cleared when the LVMC is restarted (by switching power on or by pressing one of the „Reboot LVMC“ or
„Start“ buttons), or when the analysis is reset (by pressing the „Reset Analysis“ button).
Explanation of the shown values:
“Object Count”:
The number of objects that passed the sensing area.
“Lowest Uncovered Time”:
The lowest time the sensing area was uncovered.
“Estimated Speed”:
The estimated average passing speed of all objects that passed the sensing
area. The average maximum size and the average passing time are used to
carry out the calculation.
“Lowest Passing Time”:
The lowest passing time measured.