14.3
Embodiment DO: 5 Digital Outputs
Assignment D-Sub Connector Embodiment DO
Pin Assignment
1
Shield (The shield must be connected at both cable ends to the respective
device housing.)
6
Ground (0V)
2
Power Supply (+24V)
4
Common switching voltage for optocoupler outputs (Pins 3, 5, 7,8 und 9)
8
Output 3
Optocoupler outputs
Positive polarity:
When active, the transistor is conductive
Negative polarity:
When active, the transistor is not conducting
7
Output 2
3
Output 1
(Monitoring 2)
9
Output 4
5
Output 5