4.14
External Channel Selection via Digital Inputs or Toggle Switch
Light curtains with digital inputs or digital inputs/outputs (I/Os) offer the possibility of dynamically selecting
a channel via an external device. At variants with toggle switch, the dynamic assignment can be done by
manually toggling the switch. For example, an output can be configured in such a way that a pulse is output
each time the currently selected channel detects an object.
4.14.1
Channel Selection via Digital Inputs
Via the inputs or inputs/outputs (I/Os), each of the four available channels can be selected. The following
table provides information on the assignment of the status of the two inputs to the channel number:
Input 2 or I/O 2
Input 1 or I/O 1
Corresponding Binary Code Selected Channel
0
0
00
1
0
1
01
2
1
0
10
3
1
1
11
4
4.14.2
Channel Selection via Toggle Switch
By the toggle switch, one of the channels 1 to 3 can be selected. The following table provides information
about the assignment of the toggle switch position to the channel number:
Toggle Switch Position
Selected Channel
Position A
1
Position B
2
Position C
3