Interface A2, Release Date: 02.03.2022
Page 34
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
o
“’All channels combined in automatic mode’ default configuration”:
The channels work in combination in automatic mode, the light curtain autonomously configures
the settings “Minimum Area” and “Gap Suppression Time” at runtime by use of collected data on
the objects passing the sensing area. No initial values are taken into account. The device starts
automatic assignment to a channel after 25 objects have passed the sensing area. After 10
minutes without an object having passed the sensing area, the automatic mode is restarted au-
tomatically.
o
“Default configuration of matching predecessor LV..M device (as far as possible)”:
If the LVMC replaces a device of the series LV..M with the same sensing area size, then this op-
tion allows to load a configuration which corresponds as far as possible to the standard configu-
ration of the LV..M.
Via the entry “Save Overview as HTML File”, information about the configuration, the status, and occurred
errors is saved in a HTML file. The storage location can be freely selected via a file selection window.
Via the entry “Print overview“, information about the configuration, the status, and occurred errors can be
printed on a connected printer.
Via the entry “Save Analysis Data as HTML File”, the currently available analysis data are saved in an
HTML file. The storage location can be freely selected via a file selection window.
Via the entry “Print Analysis Data”, the currently available analysis data are printed on a connected print-
er.
Via the entry “Setup Page Layout“, the page layout for print functions can be defined. You can specify the
paper size, orientation and margins.
Via the entry “Choose Folder and Filename to Save Captured Sensor Images to”, a folder and a file name
can be selected that will be used to save images captured using the analysis function.
Via the entry “Save Current Sensor Image to File”, the captured sensor image currently displayed on the
page “Analysis” is saved. The storage location can be freely selected via a file selection window.
Via the entry “Save Current Histogram to File”, the histogram currently displayed on the “Statistics & Au-
tomatic” page is saved. The storage location can be freely selected via a file selection window.
Via the entry “Update LVMC Firmware”, the firmware of a LVMC connected by USB can be updated. For
this entry to be available, the CMT must not be connected to the LVMC.
Via the entry “New CMT available? - Download and Install it” can be checked if a new version of the CMT
is available. If so, the installation file can be downloaded and the software automatically installed.
Via the entry “New Firmware available? - Download and update LVMC” can be checked if new firmware is
available for the light curtain currently connected to the CMT. If so, it can be downloaded and automati-
cally installed.