4.15
Configuration of the Inputs and Outputs
Depending on the version, the LVMC offers a different number of inputs, outputs and bidirectional in-
puts/outputs (I/Os) to which a parameterizable function can be assigned. The following functions are availa-
ble:
“not assigned”:
Configured as unused output that is never set.
“Monitoring 1 (Warning)”:
The output is assigned to the warning signal “Monitoring 1”.
“Object Stuck”:
The output is assigned to the stuck object detection. The signal is set when
an object is convering the sensing area for longer than the given 'Maximum
Permissible Passing Time'.
“Object has entered the
sensing area”:
The signal is set when an object has entered the sensing area.
“Channel x: Detection”:
The output is assigned to channel x in mode “detection”: The signal is set
when an object is detected by the assigned channel.
“Channel x: Quantity”:
The output is assigned to channel x in mode “quantity”: The signal is set
when the by parameter “Quantity” defined number of objects is detected by
the assigned channel.
“Channels 1, 3, and 4:
Detection”:
The output is assigned to channels 1, 3, and 4 in mode “detection”: The
signal is set when an object is detected by any of these three channels.
“Channels 3 and 4:
Detection”:
The output is assigned to channels 3 and 4 in mode “detection”: The signal
is set when an object is detected by any of these two channels.
“All Channels: Detection”:
The output is assigned to all channels in mode “detection”: The signal is set
when an object is detected by any channel.
“All Channels: Quantity”:
The output is assigned to all channels in mode “quantity”: The signal is set
when the by parameter “Quantity” defined number of objects is detected by
all channels together.
“All Channels:
Detection, Length-Coded”:
The output is assigned to all channels in mode „detection“, the duration the
signal is set depends on the number of the channel that detected the object:
The signal is set when an object is detected by any channel. The duration
the signal is set is given by the channel number multiplied by the value set
in parameter “Duration”.
“All Channels:
Detection, Pulse-Coded”:
The output is assigned to all channels in mode “detection”. The signal is
repeatedly set according to the number of the channel that has detected the
object. (Channel 1: signal is set once, channel 4: signal is set four times.)
The signal is set for the time specified by parameter “Duration”. The time
between two pulses is also equal to the value set in parameter „Duration“
“ All Channels:
Detection, Pulse-Coded,
w/o Channel 1”:
The output is assigned to all channels in mode “detection”. The signal is
repeatedly set according to the by 1 decremented number of the channel
that has detected the object. (Channel 1: signal is not set, channel 1: signal
is set once, channel 4: signal is set three times.) The signal is set for the
time specified by parameter “Duration”. The time between two pulses is
also equal to the value set in parameter “Duration”.