Interface A2, Release Date: 02.03.2022
Page 63
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
“Average Passing Time”:
The average passing time measured.
“Highest Passing Time”:
The highest passing time measured.
“Lowest Minimum Size”:
The lowest minimum size measured, when 15 percent of the beginning and
of the end of each object are cut-off.
“Lowest Maximum Size”:
The lowest maximum size measured.
“Average Maximum Size”:
The average of the maximum size of all object measured.
“Highest Maximum Size”:
The highest maximum size measured.
“Minimum Area”:
The minimum area measured.
“Average Area”:
The average area measured.
“Maximum Area”:
The maximum area measured.
5.12.4
Section “Continuous Data”
The “Continuous Data” section continuously displays information on the actual sensor status. The displayed
values are cleared when the LVMC is restarted (by switching power on or by pressing one of the „Reboot
LVMC“ or „Start“ buttons), or when the analysis is reset (by pressing the „Reset Analysis“ button).
Explanation of the shown values:
“Current Size”:
The object size currently measured by the sensor.
“Minimum Size”:
The minimum object size measured since the LVMC was started.
“Maximum Size”:
The maximum object size measured since the LVMC was started.
“(Un-)Covered Time”:
If the sensing area is covered by a passing object, this value shows the elapsed
time since it has entered the sensing area.
If the sensing area is uncovered, this values shows the elapsed time since the last
object has left the sensing area. If no object has passed the sensing area since
the LVMC was started, the time the LVMC is in state “running” is shown.
5.12.5
Section “Settings”
In the section „Settings”, the fifth channel, the analysis function, and the display of the sensor image are con-
figured.