Interface A2, Release Date: 02.03.2022
Page 53
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: support@optronic.ch
web: www.optronic.ch
“Duration”:
For assignment “All Channels: Detection, Length-Coded”, this parameter defines the time
that will be multiplied with the channel number. Please read the description to parameter
“Assignment” for more information.
For all other assignments, this parameter defines the duration for which the signal is set
on the output.
“Offset”:
Setting the signal at the output can be delayed. The delay can be defined by this parame-
ter.
“Quantity”:
The object quantity to count up to for the output.
This parameter is only available, if the output is assigned to a channel in mode “quantity”.