“All Channels: Detection, Pulse-Coded”:
The output is assigned to all channels in mode “detection”. The signal is repeatedly set
according to the number of the channel that has detected the object. (Channel 1: signal
is set once, channel 4: signal is set four times.) The signal is set for the time specified
by parameter “Duration”. The time between two pulses is also equal to the value set in
parameter “Duration”.
“All Channels: Detection, Pulse-Coded, w/o Channel 1”:
The output is assigned to all channels in mode “detection”. The signal is repeatedly set
according to the by 1 decremented number of the channel that has detected the object.
(Channel 1: signal is not set, channel 1: signal is set once, channel 4: signal is set three
times.) The signal is set for the time specified by parameter “Duration”. The time be-
tween two pulses is also equal to the value set in parameter “Duration”.
“All Channels: Detection, Binary-Coded”:
Outputs 3 to 5 are assigned to all channels in mode “detection”, output 3 is set when an
object is detected, outputs 4 and 5 are set according the number of the channel that de-
tected the object: The channel number minus 1 is output in binary notation on outputs 4
and 5. Output 4 is the lower bit, output 5 the higher one. Output 3 is set while the chan-
nel number is valid on outputs 4 and 5.
“Reset Counters”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the object counters of all channels and signals are reset to 0.
„Automatic Mode Restart“:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the automatic mode is restarted. All collected data and learned information
about objects that have previously passed the sensing area is flushed.
“Automatic Mode Restart/Reset Counters”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the automatic mode is restarted and the object counters of all channels and
signals are reset to 0.
“Stop Object Detection Timer”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the object detection counter is stopped.
“Start General Purpose Timer”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the general purpose timer is started.
“Stop General Purpose Timer”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the general purpose timer is stopped.
“Start & Stop General Purpose Timer”:
On detection of the active edge of this input signal (the active edge is selected by the
polarity), the general purpose timer is started and stopped.