Safety 

1.1

 

Intended Use 

The LVMC digital light curtain is a sensor for detecting, counting, measuring and classifying arbitrary objects. 
Use the device only for the purpose stated in this documentation. At any time, the light curtain may only be 
used within the limits of the prescribed and specified technical data and operating conditions. 
The light curtain is particularly not suitable for subsequent applications: Under water, in potentially explosive 
areas, in hot (more than +50°C) or cold (less than 0°C) areas, in condensing humidity, and in areas with flying 
sparks. 
The light curtain must not be used in safety applications, in particular not to protect against personal injury. It 
must not be used as a safety component in accordance with the EU Machinery Directive. 
In the event of improper use, modification or manipulation, any warranty is void, and any responsibility and 
liability of OPTRONIC AG for any damage or consequential loss caused thereby is excluded. 
Only use original OPTRONIC AG accessories or accessories recommended by OPTRONIC AG. Read the rele-
vant documentation carefully before putting the device into operation. 
The operator of the system in which the light curtain is integrated is responsible for compliance with national 
and international safety and accident prevention regulations (e.g. EN292, EN60204). 

1.2

 

Safety Instructions 

1.2.1

 

General Safety Instructions to Protect Against Physical Damage 

The instructions for the power supply must be observed. No other type of power supply than that described 
in this manual may be used 
All cables must be routed in such a way that nobody can step on them or trip over them 
Work on electrical equipment poses a safety risk and must be specially secured. The light curtain may there-
fore  only  be  installed  and  connected  by  a  specialist  in  a  voltage-free  state.  During  this  time,  the  machine 
must be switched off and secured against being switched on again. 

1.2.2

 

General instructions to Avoid Damage to the Device 

In case of faulty connection with other devices or a faulty power supply, there is a risk that the light curtain 
will be damaged. Read the relevant instructions before establishing the connection and read the documenta-
tion before commissioning. 
 

Содержание LVMC

Страница 1: ...9 027 82 OPTRONIC AG SWITZERLAND Unteregger Strasse 53 CH 9403 Goldach Phone 41 0 71 844 02 00 Fax 41 0 71 844 02 10 e mail support optronic ch web www optronic ch LVMC Digital Light Curtain for Detec...

Страница 2: ...Fax 41 0 71 844 02 10 e mail support optronic ch web www optronic ch 2021 OPTRONIC AG All rights to text and images reserved It is not permitted to reproduce this user manual or parts thereof without...

Страница 3: ...tion of the Dimension 9 3 1 2 Connectors Status LED and Toggle Switch 9 3 2 Software 9 3 2 1 Downloading 10 3 2 2 Installing 10 3 3 Power Supply 10 3 3 1 Supplying Power via D Sub Connector 10 3 3 2 S...

Страница 4: ...el Selection via Toggle Switch 22 4 15 Configuration of the Inputs and Outputs 23 4 16 Timer 25 4 17 Speed Measurement 25 4 18 Date and Time 25 4 19 Analysis Function 26 4 20 Histogram and Statistical...

Страница 5: ...tus Page 55 5 11 1 Section General Status Information 56 5 11 2 Section Ethernet State 57 5 11 3 Section Channel Status 57 5 11 4 Section Output Counter Reading 58 5 11 5 Section Timer Status 58 5 11...

Страница 6: ...Server Access by Web Browser 76 7 LVMC RC Remote Control via Ethernet 82 8 Dimensions Mounting 85 9 Sensing Area End Section 85 10 Part Name 86 11 Part Number 87 12 Available Dimensions Minimum Objec...

Страница 7: ...AG for any damage or consequential loss caused thereby is excluded Only use original OPTRONIC AG accessories or accessories recommended by OPTRONIC AG Read the rele vant documentation carefully befor...

Страница 8: ...ditions and temperature are continuously monitored and automatically taken into account during operation Correct functioning of hardware and software is continuously monitored Objects stuck in the sen...

Страница 9: ...a cap against contamination They can be removed manually Depending on the version a toggle switch or a three color status LED is integrated All these elements are located on the front of the device Th...

Страница 10: ...alling Install the software on your PC by running the installer The installer will guide you through the installation so that it should be completed in a few seconds If you are not logged in with ad m...

Страница 11: ...rder to connect to the LVMC via Ethernet you need to know its IP address The easiest way to do this is to connect to the LVMC via USB as described in the previous chapter 3 5 1 The currently used addr...

Страница 12: ...see the minimum sizes of all four existing channels These are the given minimum object sizes starting from which the channels count an object passing the sensing area Auf On the status page you will...

Страница 13: ...CMT displays the error message directly in a separate window In addition the error message can also be viewed on page Error Log Once the sensing area is free again the light curtain will be ready to...

Страница 14: ...tching to the administrator access level but none is set on delivery To switch from the user access level to the administrator access level select entry Switch to Administrator Access Level in menu Mi...

Страница 15: ...do is activate the HTTP server on the configuration page You can find the setting in the sec tion Ethernet Configuration under HTTP Server Select the setting Read Only Once you have made the change t...

Страница 16: ...tects passing objects and processes the recorded data according to the settings made in advance In this mode no chang es can be made to the configuration and no operating functions can be triggered In...

Страница 17: ...orm of gaps can be suppressed Enter the maximum time a gap that should be sup pressed can last Minimum Expected Passing Time The minimum time a part is assumed to cover the sensing area If an object i...

Страница 18: ...is guided through the light curtain and the conveyor belt is not sufficiently flat the mov ing belt may be detected under certain circumstances and may lead to a considerable number of disturbing obje...

Страница 19: ...but not channel 4 Among the selected chan nels channel 3 now has the largest minimum size 4mm and the object is therefore assigned to this chan nel Five object detection methods are available Each ch...

Страница 20: ...annel 1 The parameters Minimum Area and Gap Suppression Time are calculated automatically and continuously for channels 2 to 4 using the given parameter Bad Rate the entered percentage of objects that...

Страница 21: ...on The output is active when the light curtain is in the operating mode running and The maximum permissible degree of contamination has not been exceeded Possibly operational readi ness can be restore...

Страница 22: ...e configured in such a way that a pulse is output each time the currently selected channel detects an object 4 14 1 Channel Selection via Digital Inputs Via the inputs or inputs outputs I Os each of t...

Страница 23: ...o channels 3 and 4 in mode detection The signal is set when an object is detected by any of these two channels All Channels Detection The output is assigned to all channels in mode detection The signa...

Страница 24: ...dge of this input signal the active edge is se lected by the polarity the automatic mode is restarted and the object coun ters of all channels and signals are reset to 0 Stop Object Detection Timer On...

Страница 25: ...ible to determine the speed of an object passing the sensing areas of the two light curtains 4 17 Speed Measurement An LVMC with connected CMT can be used for speed measurement It is based on the two...

Страница 26: ...eration the LVMC continuously collects statistical data on the area and the passing time of the objects passing the sensing area Among other purposes this data is used for automatic configuration in a...

Страница 27: ...object size g can be calculated according to the following formula assuming that the environmental conditions are good d 0 0006 b 1 0mm 0 02 g 0 002 b 0 2mm Thus under good environmental conditions a...

Страница 28: ...onnection can be re initialized by briefly disconnecting the USB cable The connection should then be re established automatically 4 25 Communication via Ethernet On delivery the Ethernet network inter...

Страница 29: ...a running light ending at the side where the electronics is located The duration of a pass can be defined in the CMT Bouncing Light The sensor shows a running light that bounces from one end to the ot...

Страница 30: ...are incorporates significant new features that bring changes to the interface between the LVMC firmware and the CMT 5 1 Requirements The LVMC CMT runs on PCs with Windows 8 or Windows 10 operating sys...

Страница 31: ...5 4 Uninstalling the Software Each installed CMT software version can be uninstalled separately Uninstalling can be done via the Control Panel or directly via the specific entry in the menu For examp...

Страница 32: ...cess level can optionally be secured by a password If an administrator password is set it must be entered to authorize the change A password is defined via the entry Set Admin istrator Password in the...

Страница 33: ...figuration of the LVMC can be saved to a file The storage location can be freely selected via a file selection window Via the entry Load Configuration from File a configuration previously stored in a...

Страница 34: ...inter Via the entry Save Analysis Data as HTML File the currently available analysis data are saved in an HTML file The storage location can be freely selected via a file selection window Via the entr...

Страница 35: ...thernet can be established Once the connection has been established the five pages Configuration Status Analysis Statistics Automatic and Error Log are available in the program window in addition to t...

Страница 36: ...assword is set it must be entered before assigning a new password For security reasons the new password must be entered twice Via the entry Change CMT Password the password required for access control...

Страница 37: ...en the hypothetical speed corresponding to the currently elapsed time is displayed In the stopped mode a speed value is not displayed until the timer has been stopped For each timer the selection box...

Страница 38: ...ation of objects A label and an image can be specified per channel The picture and the label of a channel are displayed in the demonstration if an object that has passed the sensing area has been assi...

Страница 39: ...stration is started A new window opens when the first entry is selected The second entry starts the demonstration in full screen mode which can be terminated by pressing the Es cape key At the left bo...

Страница 40: ...the CMT software can be shown The software version and the interface version are displayed besides other information Via the entry Show Tool Tips the display of tool tips can be enabled Via the entry...

Страница 41: ...ers the last input made and automatically offers it again at the next connection attempt Then the CMT asks for the password the connection is secured with The CMT password can be set in the CMT via th...

Страница 42: ...the Ethernet network connection can be found The second section Sensor configuration contains settings for the sensor including the object detection method If the object detection method All channels...

Страница 43: ...tion of the available settings IP Address The Ethernet IP address that is used when DHCP is turned off Modifying this setting is only possible if DHCP is deactivated A change will not be active until...

Страница 44: ...reported Basically two methods are supported separately and combined In mode separately each channel works independent from all others A channel detects a passing object if its geometry and the passin...

Страница 45: ...ode it is expected that only one object type is passing the sensing area The task is to filter out faulty objects with an area deviating from the standard Therefore the LVMC contiguously learns by use...

Страница 46: ...state stopped notification method The minimum value is 250ms and the value must be a multiple of 250ms Minimum Required Passing Time The minimum passing time of an object By increasing this value the...

Страница 47: ...learned about a number of objects that have passed the sensing area before Preset Values Quantity The quantity of objects the preset values are adjusted to during automatic mode initialization when ch...

Страница 48: ...start function of the automatic mode is enabled This function can be enabled by marking checkbox Self Restart Mode Captured Quantity The number of objects used for learning Average Area The average ar...

Страница 49: ...the area must be entered in unit time multiplied by length This parameter can be used as a replacement for channel parameters Minimum Size and Minimum Passing Time as they also define a simplified are...

Страница 50: ...Channel x Quantity The output is assigned to channel x in mode quantity The signal is set when the by pa rameter Quantity defined number of objects is detected by the assigned channel Channels 1 3 and...

Страница 51: ...number minus 1 is output in binary notation on outputs 4 and 5 Output 4 is the lower bit output 5 the higher one Output 3 is set while the chan nel number is valid on outputs 4 and 5 Reset Counters On...

Страница 52: ...that the optocoupler of this output pin is conduct ing when the output is not set and open when it is set For an input a positive polarity means that the input is set when the optocoupler of this inp...

Страница 53: ...rameter defines the time that will be multiplied with the channel number Please read the description to parameter Assignment for more information For all other assignments this parameter defines the d...

Страница 54: ...ning the Stop button is displayed Press the Stop button to switch to the stopped operating mode Store Configuration The text of this button is shown in red when the content of the volatile con figurat...

Страница 55: ...section Ethernet State the currently used Ethernet parameterization can be read the third section Channel Status contains information on the channels The fourth section shows the counter readings of...

Страница 56: ...runs during which an error has occurred are counted Uptime Shows how long it has been since the last power up or restart of the LVMC Last Start Before Shows how long it has been since the LVMC has en...

Страница 57: ...cts of this channel This value is lower than the minimum size set for this channel on the configuration page A safety margin is subtracted in order to guarantee that no objects get missed Count The nu...

Страница 58: ...been configured as inputs Example of a device with 5 outputs or a device with 3 outputs and 2 inputs outputs I Os where both I Os have been configured as outputs Explanation of the shown values Outpu...

Страница 59: ...time of the general purpose timer It is 0 0s if the timer is never stopped since the LVMC was started by power on or pressing one of the buttons Reboot LVMC or Start or when button Reset General Purp...

Страница 60: ...d All other settings are located on the analysis page The fifth channel has no minimum passing time minimum area and minimum expected passing time The gap suppression time can be speci fied The analys...

Страница 61: ...and after The user has the choice whether the captured image should be displayed left aligned or centered The cen tered mode can be used to display symmetrical objects such as a screw that has passed...

Страница 62: ...r when the analysis is reset by pressing the Reset Analysis button Explanation of the shown values Minimum Size The minimum size of the last object detected when 15 percent of the beginning and of the...

Страница 63: ...ction continuously displays information on the actual sensor status The displayed values are cleared when the LVMC is restarted by switching power on or by pressing one of the Reboot LVMC or Start but...

Страница 64: ...ine Additionally for each chan nel a blue hatched vertical line shows the minimum object size the chan nel is configured to detect Two versions of these values lines exist The specified entered values...

Страница 65: ...hat is used to store the next sensor im age It can be set by entry Choose Folder and Filename to Save Captured Sensor Images to in menu File 5 12 7 Buttons The analysis page offers three buttons at th...

Страница 66: ...m The Statistics Data section below contains the recorded statistical data When the automatic mode is activated there is a third section named Automatic Mode Data It contains information on the runnin...

Страница 67: ...histogram is not displayed until statistical data has been collected for 10 ob jects that have passed the sensing area The data from these 10 objects is used to automatically determine the maximum and...

Страница 68: ...n auto matic mode Passing Time Average The average passing time of all objects captured in automatic mode Passing Time Standard Deviation The standard deviation of the passing time of all objects capt...

Страница 69: ...the run number and the time elapsed since the last restart are also displayed In addition the date and time of the occurrence of the error are displayed if the LVMC could obtain date and time from an...

Страница 70: ...volatile and also the nonvolatile error log 5 15 Display of the LVMC Properties Via the entry Show Information about this LVMC in the Miscellaneous menu the fixed properties of the light curtain can b...

Страница 71: ...ects supported by this LVMC and its firmware Channels The number of channels supported by the LVMC Outputs I Os The number of output signals supported by the LVMC Interface The version of the interfac...

Страница 72: ...naling of operational readiness Immediately after opening the dialog box all available optocoupler outputs are open For each available output the state can now be changed from Open to Conductive Chang...

Страница 73: ...er a specified number of runs The frequency the activated outputs are to oscillate with can be entered in Hertz or set via a slider bar in the range from 1Hz to 16 6Hz The input is automatically corre...

Страница 74: ...settings Frequency To define the frequency the optocoupler outputs should toggle with The slider is adjusted automatically Slider Bar Move the slider to define the frequency the optocoupler outputs s...

Страница 75: ...ous menu and if necessary activated again by selecting the Show Notification Messages en try The most likely notice message you ll see informs you that you ve made a change to the configuration but ha...

Страница 76: ...by entering the IP address of the LVMC in the address bar of the web browser Depending on your browser you may have to put the abbreviation http in front of the address Your web browser should now dis...

Страница 77: ...41 0 71 844 02 10 e mail support optronic ch web www optronic ch On page Configuration the sections Sensor Configuration Channel Configuration and I O Configura tion are displayed according to the co...

Страница 78: ...SWITZERLAND Unteregger Strasse 53 CH 9403 Goldach Phone 41 0 71 844 02 00 Fax 41 0 71 844 02 10 e mail support optronic ch web www optronic ch The Status page contains the same information as the stat...

Страница 79: ...9 LVMC User Manul A2 499 027 82 OPTRONIC AG SWITZERLAND Unteregger Strasse 53 CH 9403 Goldach Phone 41 0 71 844 02 00 Fax 41 0 71 844 02 10 e mail support optronic ch web www optronic ch The current e...

Страница 80: ...H 9403 Goldach Phone 41 0 71 844 02 00 Fax 41 0 71 844 02 10 e mail support optronic ch web www optronic ch The Network page provides network specific information In addition to the currently used net...

Страница 81: ...mail support optronic ch web www optronic ch The Settings page is only available if the HTTP server is activated in Full Access mode and if at least one output is assigned a function in mode quantity...

Страница 82: ...ined in the in terface definition which must be queried by the client and compared with its own version It is the client s responsibility to ensure that the version numbers and thus the interface defi...

Страница 83: ...ANNELS To set the configuration of all supported channels the minimum size the minimum area The minimum passing time the gap suppression time and the minimum expected passing time RC_COMMAND_PUT_ CONF...

Страница 84: ...is unencrypted The addressed LVMC must also be configured for encrypted or unencrypted commu nication The key transferred with the switch k or key must match the key stored in the LVMC All availa ble...

Страница 85: ...sed to mount the device reliable The maximun thread reach is 20mm Attention On delivery there is a screw in the middle M5 thread at the bottom of the device as protection against contamination orange...

Страница 86: ...mm yyy Sensing Area Length in mm 50 50mm 100 100mm 150 150mm 200 200mm 250 250mm 300 300mm 400 400mm z w o Selection of the channel by toggle switch or by software no digital optocoupler inputs 3 digi...

Страница 87: ...th in mm 1 50mm 2 100mm 3 150mm 4 200mm 5 250mm 6 300mm 7 400mm f 1 Selection of the channel by two digital optocoupler inputs or by software 2 digital optocoupler inputs 3 digital optocoupler outputs...

Страница 88: ...er z in the part name Part Name Minimum Object Size Dimension Sensing Area Width x Sensing Area Length External Dimensions Width x Length LVMC100 50Mz 1mm 100mm x 52mm 160 mm x 165mm LVMC100 100Mz 1mm...

Страница 89: ...100 50M1 LVMC100 50M LV100 50M2 LVMC100 50M1 LV100 50M3 LVMC100 50M1 LV100 50M4 LVMC100 50M1 LV100M LVMC100 100M LV100M1 LVMC100 100M1 LV100M2 LVMC100 100M1 LV100M3 LVMC100 100M1 LV100M4 LVMC100 100M1...

Страница 90: ...e channel by toggle switch or by software 3 digital optocoupler outputs no digital optocoupler inputs DI Selection of the channel by two digital optocoupler inputs or by software 3 digital optocoupler...

Страница 91: ...nector Embodiment WS Pin Assignment 1 Shield The shield must be connected at both cable ends to the respective device housing 6 Ground 0V 2 Power Supply 24V 4 Common switching voltage for optocoupler...

Страница 92: ...nment D Sub Connector Embodiment DI Pin Assignment 1 Shield The shield must be connected at both cable ends to the respective device housing 6 Ground 0V 2 Power Supply 24V 4 Common switching voltage f...

Страница 93: ...ignment D Sub Connector Embodiment DO Pin Assignment 1 Shield The shield must be connected at both cable ends to the respective device housing 6 Ground 0V 2 Power Supply 24V 4 Common switching voltage...

Страница 94: ...oltage for optocoupler outputs and optocoupler I Os Pins 3 5 7 8 und 9 8 Output 3 Optocoupler outputs Positive polarity When active the transistor is conductive Negative polarity When active the trans...

Страница 95: ...tage 18 24 30 V DC Current Consumption 200 mA Power Supply via Power over Ethernet PoE Supply Voltage 36 48 57 V DC Current Consumption 150 mA 16 Operating Conditions Protection class IP53 Permissible...

Страница 96: ...71 844 02 10 e mail support optronic ch web www optronic ch 18 System Requirements for CMT The requirements for the computer used to run the CMT software are as follows Operating system Windows 8 or l...

Страница 97: ...was founded 1961 as company for development manufactur ing as well as marketing of optoelectron ic devices Nowadays the service offering of OP TRONIC AG covers solutions for special requirements in t...

Отзывы: