5.11.1
Section “General Status Information”
The “General Status Information” section displays general information about the status of the light curtain.
The appearance of this section depends on the device type and the settings in the “I/O Configuration” section
of the Configuration page.
Example of a device with 5 outputs, or a device with 3 outputs and 2 inputs/outputs (I/Os) where both I/Os
have been configured as outputs:
Example of a device with 3 outputs and 2 inputs, or a device with 3 outputs and 2 inputs/outputs (I/Os)
where both I/Os have been configured as inputs:
Explanation of the shown values:
“State”:
Shows if the LVMC is running or stopped. The LVMC detects objects only in state
“running”. Configuration changes can only be made in state “stopped”. After a
restart, the LVMC automatically enters state “running”, if no error occurs.
“Run”:
This entry shows the number of the current run. A new run starts when the LVMC
is restarted, but only runs during which an error has occurred are counted.
“Uptime”:
Shows how long it has been since the last power-up or restart of the LVMC.
“Last Start Before”:
Shows how long it has been since the LVMC has entered state “running”.
“Date”:
Shows the current date, if the LVMC was able to fetch date and time from an NTP
server.
“Time”:
Shows the current time, if the LVMC was able to fetch date and time from an NTP
server.
“Output 1
(Monitoring 2):
State”:
Current state of the optocoupler output 1 and the assigned signal “Monitoring 2”.
The color shows the signal state, the text the optocoupler output state. If the field
is red, signal “Monitoring 2” is inactive. If it is green, the signal is active. “OFF”
means that the optocoupler output is open, “ON” that it is conducting.
„Output x: State“
or
“I/O x (Output y):
State”:
Current state of the optocoupler output and the assigned signal. The color shows
the signal state, the text the optocoupler state. If the field is black, the signal is
inactive. If it is yellow, the signal is active. “OFF” means that the optocoupler out-
put is open, ON” that it is conducting.
„I/O x (Input y):
State”:
Current state of the optocoupler input and the assigned signal. The color shows
the signal state, the text the optocoupler state. If the field is black, the signal is
inactive. If it is yellow, the signal is active. “OFF” means that the optocoupler input
is open, “ON” that it is conducting.