Interface A2, Release Date: 02.03.2022
Page 58
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
“Passing Time:
Maximum“:
The maximum passing time of all objects detected by this channel. The value is
cleared when the LVMC is started (by power on, or pressing one of the buttons
“Reboot LVMC” or “Start”), or when the statistics is reset (by pressing on button
“Reset Status”).
5.11.4
Section “Output Counter Reading”
The section “Output Counter Reading” shows the counter readings of all available outputs and of the I/Os
that are configured as outputs. The appearance of this section therefore depends on the device type and
settings in the “I/O Configuration” section on the configuration page.
Example of a device with 3 outputs and 2 inputs, or a device with 3 outputs and 2 inputs/outputs (I/Os)
where both I/Os have been configured as inputs:
Example of a device with 5 outputs, or a device with 3 outputs and 2 inputs/outputs (I/Os) where both I/Os
have been configured as outputs:
Explanation of the shown values:
„Output x: Count“
or
“I/O x (Output y): Count”:
Shows how often the output has been switched to active.
The value is cleared at power on, or by pressing one of the buttons “Reboot
LVMC” or 2Reset Counters”. If an I/O is assigned to function “Reset Coun-
ters”, the value can also be cleared by a positive or negative edge of this sig-
nal.
5.11.5
Section “Timer Status”
The "Timer Status" section is only available if one or both timers are activated. For each timer activated, it
shows the time currently running and the time last stopped.
Example of a device with 3 outputs and 2 inputs/outputs (I/Os) where one of the two I/Os has been assigned
the function “Stop Object Detection Timer”:
Example of a device with 3 outputs and 2 inputs/outputs (I/Os) where one of the two I/Os has been assigned
the function “Stop Object Detection Timer” and the other one of the functions “Start General Purpose Timer”,
“Stop General Purpose Timer”, or “Start & Stop General Purpose Timer”: