Interface A2, Release Date: 02.03.2022
Page 91
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
14.1
Embodiment WS: Toggle Switch and 3 Digital Outputs
Assignment D-Sub Connector Embodiment WS
Pin Assignment
1
Shield (The shield must be connected at both cable ends to the respective
device housing.)
6
Ground (0V)
2
Power Supply (+24V)
4
Common switching voltage for optocoupler outputs (Pin 3, 7 und 8)
8
Output 3
Optocoupler outputs
Positive polarity:
When active, the transistor is conductive
Negative polarity:
When active, the transistor is not conducting
7
Output 2
3
Output 1
(Monitoring 2)
9
Not assigned
No function assigned
Leave these pins unconnected
5
not assigned
D-Sub Connector