3.7
Modifying Settings
After each restart of the light curtain, all inputs and controls are disabled, i.e. you can only observe the light
curtain. One reason for this is that the light curtain knows two access levels, the user access level and the
administrator access level. Only at the administrative access level you have full access to all functions and
inputs. A password can be set for switching to the administrator access level, but none is set on delivery. To
switch from the user access level to the administrator access level, select entry “Switch to Administrator
Access Level” in menu “Miscellaneous”.
But you still probably can not change any input values. The reason is that the LVMC is in “run“ mode, i.e. it
detects passing objects and processes the recorded data according to the settings. No entries can be made
in this mode. You must "stop" it first and this is done by pressing the "Stop" button.
Now you can, for example, change the minimum size of channel 1 or load the factory settings via the “Re-
store Default Configuration“ entry in the “File” menu and thus return all settings to the factory settings.
Press the “Start” button to put the LCMC back in “running” mode.
It takes about a second for the start to complete.