Interface A2, Release Date: 02.03.2022
Page 66
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
5.13
Statistics & Automatic Page
On the “Statistics & Automatic” page, the collected statistical data with associated histogram are shown. If
the object detection method “All channels combined, automatic mode, when object is leaving the sensing
area” is selected, data for the running automatic configuration of the automatic mode are displayed. The
page is divided into two or three sections: The top section “Histogram” displays the recorded histogram. The
“Statistics Data” section below contains the recorded statistical data. When the automatic mode is activated,
there is a third section named “Automatic Mode Data”. It contains information on the running automatic con-
figuration.
On the horizontal axis of the histogram, the area of the captured objects is applied. The vertical axis shows
how many objects of a given area have passed the sensing area. The histogram is automatically scaled. The
calculated area of the first 10 objects that passed the sensing area after resetting the histogram is used to
determine the minimum and maximum area that can be displayed in the histogram. This indirectly deter-
mines the maximum resolution of the horizontal axis of the histogram. The histogram is displayed for the
first time after these 10 first objects. Each additional object is plotted in the histogram, provided its area is