Interface A2, Release Date: 02.03.2022
Page 24
LVMC User Manul A2 - 499.027.82
OPTRONIC AG
SWITZERLAND
Unteregger Strasse 53
CH-9403 Goldach
Phone: +41 (0)71 844 02 00
Fax:
+41 (0)71 844 02 10
e-mail: [email protected]
web: www.optronic.ch
“All Channels:
Detection, Binary-Coded”:
Outputs 3 to 5 are assigned to all channels in mode „detection“, output 3 is
set when an object is detected, outputs 4 and 5 are set according the num-
ber of the channel that detected the object:
Channel Output 3
Output 4
Output 5
0
1
0
0
1
1
0
1
2
1
1
0
3
1
1
1
The channel number minus 1 is output in binary notation on outputs 4 and
5. Output 4 is the lower bit, output 5 the higher one. Output 3 is set while the
channel number is valid on outputs 4 and 5.
“Reset Counters”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the object counters of all channels and signals are
reset to 0.
“Automatic Mode Restart”: On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the automatic mode is restarted. All collected data
and learned information about objects that have previously passed the
sensing area is flushed.
“Automatic Mode
Restart/Reset Counters”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the automatic mode is restarted and the object coun-
ters of all channels and signals are reset to 0.
“Stop Object Detection
Timer”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the object detection counter is stopped.
“Start General Purpose
Timer'”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the general purpose timer is started.
“Stop General Purpose
Timer”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the general purpose timer is stopped.
“Start & Stop General
Purpose Timer”:
On detection of the active edge of this input signal (the active edge is se-
lected by the polarity), the general purpose timer is started and stopped.
“Channel Selection”:
I/Os 1 and 2 are used as digital inputs to select the active channel. The ac-
tive channel is used for assignments “Channel by Inputs: Detection” and
“Channel by Inputs: Quantity”.
“Channel by Switch:
Detection”:
The output is assigned to the channel selected by the switch in mode „de-
tection“: The signal is set when an object is detected by the assigned chan-
nel.
“Channel by Switch:
Quantity”:
The output is assigned to the channel selected by the switch in mode
“quantity”: The signal is set when the by parameter “quantity” defined num-
ber of objects is detected by the assigned channel.