M2DC Series Hardware Manual
124
Rev. 1.1
2018/04
400-820-9661
P-23 (JA)
Jog acceleration
Data Range
Default
Unit
Data type
0.167 - 5000
100
rps/s
DEC
The accel/decel rate for Jog moves and velocity control mode in rev/sec/sec. Setting JA overwrites both
the last JA and JL values. This means that to have different jog accel and jog decel values, you should
first send JA to set the jog accel and then send JL to set the jog decel.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where
is jog acceleration/deceleration setting, Unit is rps/s .
P-24 (JL)
Jog deceleration
Data Range
Default
Unit
Data type
0.167 - 5000
100
rps/s
DEC
The accel/decel rate for Jog moves and velocity control mode in rev/sec/sec. Setting JA overwrites both
the last JA and JL values. This means that to have different jog accel and jog decel values, you should
first send JA to set the jog accel and then send JL to set the jog decel.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where
is jog acceleration/deceleration setting, Unit is rps/s .
P-25 (VE)
Point to point Velocity
Data Range
Default
Unit
Data type
0.025 - 100
5
rps
DEC
The shaft speed for point-to-point move commands like FL, FP, FS, FD, SH, etc.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 240
Where = is target velocity setting, Unit is rps (rev/sec) .
P-26 (AC)
Point to point acceleration
Data Range
Default value
Unit
Data type
0.167 - 5000
100
rps/s
DEC
The acceleration rate used in point-to-point move commands in rev/sec/sec.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where
is point to point move acceleration setting, Unit is rps/s .
P-27 (DE)
Point to point deceleration
Data Range
Default
Unit
Data type
0.167 - 5000
100
rps/s
DEC
The deceleration rate used in point-to-point move commands in rev/sec/sec.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where
is point to point move deceleration setting, Unit is rps/s .