![Mitsubishi FR-A740-00023-EC Скачать руководство пользователя страница 342](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251342.webp)
332
Communication operation and setting
[Inverter status monitor]
* The signal within parentheses is the initial setting. The description changes depending on the setting of
Pr. 190 to Pr. 196 (output terminal function
selection)
.
Item
Instruction
Code
Bit
Length
Description
Example
Inverter
status
monitor
H7A
8bit
b0:RUN (inverter running)*
b1:Forward rotation
b2:Reverse rotation
b3:SU (up to frequency) *
b4:OL (overload) *
b5:IPF (instantaneous power failure) *
b6:FU (frequency detection)*
b7:ABC1 (alarm) *
Inverter
status
monitor
(extended)
H79
16bit
b0:RUN (inverter running) *
b1:Forward rotation
b2:Reverse rotation
b3:SU (up to frequency) *
b4:OL (overload) *
b5:IPF (instantaneous power failure) *
b6:FU (frequency detection) *
b7:ABC1 (alarm) *
b8:ABC2 (
⎯
)*
b9:
⎯
b10:
⎯
b11:
⎯
b12:
⎯
b13:
⎯
b14:
⎯
b15: Alarm occurrence
0
0
0
0
0
0
1
0
b7
b0
0
0
0
0
0
0
1
0
b7
b0
[Example 2] H80
[Example 1] H02
Stop at alarm
occurrence
During forward
rotation
0
0
0
0
0
0
1
0
b0
0
0
0
0
0
0
0
0
b15
[Example 1] H0002 During forward rotation
1
0
0
0
0
0
0
0
b0
1
0
0
0
0
0
0
0
b15
[Example 2] H8080 Stop at alarm occurrence
Содержание FR-A740-00023-EC