![Mitsubishi FR-A740-00023-EC Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251126.webp)
116
Torque control by real sensorless vector
control, vector control
4.5.3
Setting procedure of vector control (torque control)
CAUTION
⋅
The carrier frequencies are selectable from among 2k, 6k, 10k, 14kHz for vector control.
(2k and 6kHz for the 02160 or more)
Vector
Vector
Vector
Test run
Perform secure wiring.
(Refer to page 34.)
Set the motor and encoder.
(Pr. 71, Pr. 359, Pr. 369)
As required
· Perform offline auto tuning.
(Pr. 96) (refer to page 181).
· Select online auto tuning.
(Pr. 95) (refer to page
191
).
· Manual input torque control gain adjustment
(refer to page 122)
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81)
(Refer to page 87.)
Set the motor capacity (kW) in
Pr. 80
Motor capacity
and set the number
of motor poles in
Pr. 81
Number of motor poles
.
(V/F control is performed when the setting is "9999" (initial value).)
Mount the FR-A7AP.
Set
Pr. 71 Applied motor
,
Pr. 359 Encoder rotation direction
and
Pr. 369
Number of encoder pulses
according to the motor and encoder used.
(Refer to page 36.)
Select a control method.
(Refer to page 87.)
Set either "1" (torque control), "2" (speed-torque switchover) or "5"
(position-torque switchover) in
Pr. 800
and make torque control valid.
Set the torque command.
(Pr. 804)
(Refer to page 117.)
Set the speed limit.
(Pr. 807)
(Refer to page 119.)
Содержание FR-A740-00023-EC
Страница 58: ...48 MEMO...
Страница 70: ...60 MEMO...
Страница 400: ...390 MEMO...
Страница 450: ...440 MEMO...
Страница 473: ...463 MEMO...