96
Speed control by real sensorless vector
control, vector control
Terminal 1, 4 function according to control (
⎯
: without function)
*1
When the
Pr. 868
setting is other than "0", other functions of terminal 1 (auxiliary input, override function, PID control) do not function.
*2
When the
Pr. 858
setting is other than "0", PID control and speed command from terminal 4 do not function even if the AU signal turns on.
*3
When "1" (magnetic flux command) or "4" (torque limit) is set in both
Pr. 858
and
Pr. 868
, function of terminal 1 has higher priority and terminal 4
has no function.
*4
Setting is valid only when exercising vector control with the FR-A7AP.
(5) Second torque limit level (TL signal,
Pr. 815
)
Pr. 858
Setting
*1
Pr. 868
Setting
*2
Real Sensorless Vector Control (Speed Control)
Terminal 4 function
Terminal 1 function
0
(initial value)
0
(initial value)
Speed command
(AU signal-ON)
Speed setting auxiliary
1
*4
Magnetic flux command
2
⎯
3
⎯
4
Torque limit (
Pr. 810
= 1)
5
⎯
6
*4
Torque bias (
Pr. 840
= 1 to 3)
9999
⎯
1
*4
0
(initial value)
Magnetic flux command
Speed setting auxiliary
1
*4
⎯
*3
Magnetic flux command
2
Magnetic flux command
⎯
3
⎯
4
Torque limit (
Pr. 810
= 1)
5
⎯
6
*4
Torque bias (
Pr. 840
= 1 to 3)
9999
⎯
4
*2
0
(initial value)
Torque limit (
Pr. 810
= 1)
Speed setting auxiliary
1
*4
Magnetic flux command
2
Driving torque limit (
Pr. 810
= 1)
Regenerative torque limit (
Pr. 810
= 1)
3
Torque limit (
Pr. 810
= 1)
⎯
4
⎯
*3
Torque limit (
Pr. 810
= 1)
5
Torque limit (
Pr. 810
= 1)
⎯
6
*4
Torque bias (
Pr. 840
= 1 to 3)
9999
⎯
9999
⎯
⎯
⎯
⋅
For
Pr. 815 Torque limit level 2
, the
Pr. 815
value is a torque
limit value regardless of
Pr. 810 Torque limit input method
selection
when the torque limit selection signal (TL) is on.
⋅
Set "27" in
Pr. 178 to Pr. 189 (input terminal function selection)
to assign a function to the TL signal.
CAUTION
⋅
Changing the terminal assignment using
Pr. 178 to Pr. 189 (input terminal function selection)
may affect the other functions. Please
make setting after confirming the function of each terminal.
Pr.815
Pr.815
Pr.815
Pr.815
quad4
quad2
Reverse
rotation
Forward
rotation
Torque limit
Speed
Reverse
driving
Reverse
regeneration
Rated speed
quad3
+
-
Forward
regeneration
Forward
driving
quad1