313
Selection of operation mode and operation location
4
P
ARAME
T
E
R
S
(5) Selection of control source in network operation mode
(Pr. 338, Pr. 339)
⋅
As control sources, there are the operation command sources that control the signals related to the inverter start
command and function selection and the speed command source that controls the signals related to frequency setting.
⋅
In network operation mode, the commands from the external terminals and communication (RS-485 terminals or
communication option) are as listed below.
Operation
Location
Selection
Pr. 338 Communication operation command
source
0: NET
1: External
Remarks
Pr. 339 Communication speed command
source
0: NET
1:External 2:External 0: NET
1:External 2:External
Fixed function
(Terminal-
equivalent
function)
Running frequency from
communication
NET
⎯
NET
NET
⎯
NET
Terminal 2
⎯
External
⎯
⎯
External
⎯
Terminal 4
⎯
External
⎯
External
Terminal 1
Compensation
Selec
tive
f
unc
ti
on
Pr
. 1
78 to Pr
. 1
89
se
tt
in
g
0
RL
Low speed operation com-
mand/remote setting clear
stop-on-contact selection 0
NET
External
NET
External
Pr. 59
= "0" (multi-
speeds)
Pr. 59
= "1 , 2"
(remote)
Pr. 270
= "1 , 3"
(stop-on-contact)
1
RM
Middle-speed operation
command/remote setting
deceleration
NET
External
NET
External
2
RH
High speed operation
command/remote setting
acceleration
NET
External
NET
External
3
RT
Second function selection/
Stop-on contact selection 1
NET
External
Pr. 270
= "1 , 3"
(stop-on-contact)
4
AU
Current input selection
⎯
Combined
⎯
Combined
5
JOG
Jog operation selection
⎯
External
6
CS
Selection of automatic restart
after instantaneous power
failure
External
7
OH
External thermal relay input
External
8
REX
Fifteen speed selection
NET
External
NET
External
Pr. 59
= "0"
(multi-speeds)
9
X9
Third function selection
NET
External
10
X10
Inverter operation enable
signal
External
11
X11
FR-HC connection,
instantaneous power failure
detection
External
12
X12
PU operation external
interlock
External
13
X13
External DC injection brake
operation start
NET
External
14
X14
PID control valid terminal
NET
External
NET
External
15
BRI
Brake opening completion
signal
NET
External
16
X16
PU-external operation
switchover
External
17
X17
Load pattern selection forward
rotation reverse rotation boost
NET
External
18
X18
V/F switching
NET
External
19
X19
Load torque high-speed fre-
quency
NET
External
20
X20
S-pattern acceleration/decel-
eration C switchover
NET
External
22
X22
Orientation command
NET
External
23
LX
Pre-excitation
NET
External
24
MRS
Output stop
Combined
External
Pr. 79
≠
"7"
PU operation interlock
External
Pr. 79
= "7"
When X12 signal
is not assigned
25
STOP Start self-holding selection
⎯
External
26
MC
Control mode swichover
NET
External
27
TL
Torque limit selection
NET
External
28
X28
Start-time tuning start external
input
NET
External
37
X37
Traverse function selection
NET
External