![Mitsubishi FR-A740-00023-EC Скачать руководство пользователя страница 324](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251324.webp)
314
Selection of operation mode and operation location
[Explanation of table]
External
: Control is valid only from external terminal signal.
NET
: Control only from communication is valid
Combined
: Control is valid from either of external terminal and communication.
⎯
: Control is invalid from either of external terminal and communication.
Compensation : Control by signal from external terminal is only valid when
Pr. 28 Multi-speed input compensation selection
= "1"
(6) Switching of command source by external terminal (X67)
⋅
In network operation mode, the command source switching signal (X67) can be used to switch the operation
command source and speed command source. This signal can be utilized to control the signal input from both the
external terminal and communication.
⋅
Set "67" in any of
Pr. 178 to Pr. 189
(input terminal function selection) to assign the X67 signal to the external
terminal.
⋅
When the X67 signal is off, the operation command source and speed command source are external.
S
e
le
ct
iv
e fu
n
ct
io
n
Pr
. 178
to
P
r.
18
9
s
etti
n
g
42
X42
Torque bias selection 1
NET
External
43
X43
Torque bias selection 2
NET
External
44
X44
P/PI control switchover
NET
External
50
SQ
Sequence start
NET
External
60
STF
Forward rotation command
NET
External
61
STR
Reverse rotation command
NET
External
62
RES
Reset
External
63
PTC
PID forward action switchover
External
64
X64
PID forward action switchover
NET
External
NET
External
65
X65
PU-NET operation switchover
External
66
X66
External-NET operation
switchover
External
67
X67
Command source switchover
External
68
NP
Conditional position pulse
train sign
External
69
CLR
Conditional position droop
pulse clear
External
70
X70
DC feeding operation
permission
NET
External
71
X71
DC feeding cancel
NET
External
74
X74
Magnetic flux decay output
shutoff
NET
External
REMARKS
⋅
The control source of communication is as set in
Pr. 550
and
Pr. 551
.
X67 Signal State
Operation Command Source
Speed Command Source
No signal assignment
According to
Pr. 338
According to
Pr. 339
ON
OFF
Operation is valid only from external terminal signal.
REMARKS
⋅
The ON/OFF state of the X67 signal is reflected only during a stop. It is reflected after a stop when the terminal is switched
during operation.
⋅
When the X67 signal is off, a reset via communication is disabled.
CAUTION
⋅
Changing the terminal assignment using
Pr. 178 to Pr. 189 (input terminal function selection)
may affect the other functions. Please
make setting after confirming the function of each terminal.
♦
Parameters referred to
♦
Pr. 28 Multi-speed input compensation selection
Refer to page 164.
Pr. 59 Remote function selection
Refer to page 164.
Pr. 79 Operation mode selection
Refer to page 301.
Operation
Location
Selection
Pr. 338 Communication operation command
source
0: NET
1: External
Remarks
Pr. 339 Communication speed command
source
0: NET
1:External 2:External 0: NET
1:External 2:External
Содержание FR-A740-00023-EC
Страница 58: ...48 MEMO...
Страница 70: ...60 MEMO...
Страница 400: ...390 MEMO...
Страница 450: ...440 MEMO...
Страница 473: ...463 MEMO...