![Mitsubishi FR-A740-00023-EC Скачать руководство пользователя страница 341](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251341.webp)
331
Communication operation and setting
4
P
ARAME
T
E
R
S
[Alarm data]
Refer to
page 393
for details of alarm description.
[Run command]
*1
The signal within parentheses is the initial setting. The description changes depending on the setting of
Pr. 180 to Pr. 184, Pr. 187 (input terminal
function selection) (page 222)
.
*2
The signal within parentheses is the initial setting. Since jog operation/selection of automatic restart after instantaneous power failure/start self-
holding/reset cannot be controlled by the network, bit 8 to bit 11 are invalid in the initial status. When using bit 8 to bit 11, change the signals with
Pr. 185, Pr. 186, Pr. 188, Pr. 189 (input terminal function selection) (page 222)
. (Reset can be executed with the instruction code HFD.)
Item
Instruction
Code
Bit
Length
Description
Example
Run
command
HFA
8bit
b0: AU (current input selection)
*1
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (low speed operation
command)
*1
b4: RM (middle speed operation
command)
*1
b5: RH (high speed operation
command)
*1
b6: RT (second function selection)
*1
b7: MRS (output stop)
*1
Run
command
(extended)
HF9
16bit
b0:AU (current input selection)
*1
b1:Forward rotation command
b2:Reverse rotation command
b3:RL (low speed operation command)
*1
b4:RM (middle speed operation
command)
*1
b5: RH (high speed operation
command)
*1
b6:RT (second function selection)
*1
b7:MRS (output stop)
*1
b8:JOG (Jog operation)
*2
b9:CS (selection of automatic restart after
instantaneous power failure)
*2
b10: STOP (start self-holding)
*2
b11:RES (reset)
*2
b12:
⎯
b13:
⎯
b14:
⎯
b15:
⎯
Alarm description display example (instruction code H74)
Data
Description
H00
No alarm
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
H40
E.FIN
H50
E.IPF
H51
E.UVT
H52
E.ILF
H60
E.OLT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
H91
E.PTC
HA0
E.OPT
HA3
E.OP3
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC1
E.CTE
HC2
E.P24
HC4
E.CDO
HC5
E.IOH
HC6
E.SER
HC7
E.AIE
HC8
E.USB
HD0
E.OS
HD1
E.OSD
HD2
E.ECT
Data
Description
HD3
E.OD
HD5
E.MB1
HD6
E.MB2
HD7
E.MB3
HD8
E.MB4
HD9
E.MB5
HDA
E.MB6
HDB
E.MB7
HDC
E.EP
HF1
E.1
HF2
E.2
HF3
E.3
HF6
E.6
HF7
E.7
HFB
E.11
HFD
E.13
Data
Description
For read data H30A0
(Previous alarm ...... THT)
(Latest alarm ...... OPT)
0
1
0
1 0 0 0 0
0
0
0
0
0
0
1
1
b15
b8 b7
b0
Latest alarm
(HA0)
Previous alarm
(H30)
0
0
0
0
0
0
1
0
b7
b0
[Example 1] H02 Forward rotation
[Example 2] H00 Stop
0
0
0
0
0
0
0
0
b7
b0
0
0
0
0
0
0
1
0
b0
[Example 1] H0002 Forward rotation
0
0
0
0
0
0
0
0
b15
0
0
0
0
0
0
0
0
b0
[Example 2] H0800 low speed operation
(When
Pr. 189 RES terminal function selection
is set to "0")
0
0
0
0
1
0
0
0
b15
Содержание FR-A740-00023-EC
Страница 58: ...48 MEMO...
Страница 70: ...60 MEMO...
Страница 400: ...390 MEMO...
Страница 450: ...440 MEMO...