2. SYSTEM CONFIGURATION
2 - 14
MELSEC-A
Item
Model
Description
Number of
inputs/outputs
Current
consumption
Remarks
*
Approved
[I/O allocation
module type]
5 V DC
24 V DC
standard
A1S62TCTT-
S2
Transistor output, thermocouple input
2 channels/module
PID control : ON/OFF pulse
0.19
—
A1S62TCTTB
W-S2
Transistor output, thermocouple input
2 channels/module
PID control : ON/OFF pulse, heater
wire breakage detection function
32
[Special 32-point]
0.28
—
A1S62TCRT-
S2
Transistor output, platinum
temperature-measuring resistor input
2 channels/module
PID control : ON/OFF pulse
0.19
—
A1S62TCRTB
W-S2
Transistor output, platinum
temperature-measuring resistor input
2 channels/module PID control :
ON/OFF pulse, heater wire breakage
detection function
32
[Special 32-point]
0.28
—
A1S64TCTT-
S1
Transistor output, thermocouple input
4 channels/module
PID control : ON/OFF pulse or 2-
position control
0.33
—
A1S64TCTTB
W-S1
Transistor output, thermocouple input
4 channels/module
PID control : ON/OFF pulse or 2-
position control
Heater wire breakage detection
function
32
[Special 32-point]
0.42
—
A1S64TCRT-
S1
Transistor output, thermocouple input
4 channels/module
PID control : ON/OFF pulse or 2-
position control
0.33
—
Tempera-
ture ad-
justment
module
A1S64TCRTB
W-S1
Transistor output, thermocouple input
4 channels/module
PID control : ON/FOO pulse or 2-
position control
Heater wire breakage detection function
32
[Special 32-point]
0.42
—
A1SJ71AP21
For master or local station of
MELSECNET (II) optical data link
32
[Special 32-point]
0.33
—
A1SJ71AP21-
S3
For master or local station of
MELSECNET (II) data link module system
(GI type optical fiber cable)
32
[Special 32-point]
0.33
—
MELSEC-
NET (II)
data link
module
A1SJ71AR21
For master or local station of
MELSECNET (II) coaxial data link
32
[Special 32-point]
0.8
—
A1SJ71AT21B
For master or local station of
MELSECNET/B data link system
32
[Special 32-point]
0.66
—
MELSEC-
NET/B
data link
module
A1SJ72T25B
For remote I/O station of
MELSECNET/B data link system
—
0.3
—
A1SJ71LP21
For control station, master station, and
local station of the MELSECNET/10
data link module system
(For SI type optical fiber cable, double loop)
32
[Special 32-point]
0.65
—
A1SJ71BR11
For control station, master station, and
local station of the MELSECNET/10
data link module system
(For coaxial cable, single bus)
32
[Special 32-point]
0.80
—
MELSEC-
NET/10
data link
module
A1SJ71LR21
For control station, master station, and
local station of the MELSECNET/10
data link module system
(For coaxial cable, double loop)
32
[Special 32-point]
1.14
—
CC-Link
system
master-
local
module
A1SJ61BT11
For the master station of the C.C-Link
data link system
(Dedicatedly for shielded twisted pair
cable)
32
[32 outputs]
0.40
—
UL/cUL
* : Class 2 power supply recognized by the UL/cUL Standard is required for 5-12-24 V DC modules.