APPENDICES
APP - 33
MELSEC-A
Table 2.2
Special registers list (Continue)
Number
Name
Description
Details
Applicable CPU
D9180
D9181
D9182
D9183
D9184
D9185
D9186
D9187
D9188
D9189
D9190
D9191
D9192
D9193
Remote terminal
module error
number
• Stores error code of a faulty remote terminal module
when M9060 is turned on.
• The error code storage areas for each remote terminal
module are as shown below.
D9180
D9181
D9192
D9193
Remote terminal module No.1
D9182
...
Remote
terminal
module
numbers
from 1 to 14
are set with
D9020 to
D9034.
Remote terminal module No.2
Remote terminal module No.3
Remote terminal module No.13
Remote terminal module No.14
• Error code is cleared in the following cases.
• When the RUN key switch is moved from STOP to RUN.
(D9180 to D9183 are all cleared.)
• When Yn4 of each remote terminal is set from OFF to
ON.
—
Usable with A2C
and A52G.
D9180
Limit switch
output state
torage areas for
axes 1 and 2
—
Dedicated to
A73.
D9181
Limit switch
output state
storage areas for
axes 3 and 4
—
Dedicated to
A73.
D9182
Limit switch
output state
storage areas for
axes 5 and 6
—
Dedicated to
A73.
D9183
Limit switch
output state
storage areas for
axes 7 and 8
Bit pattern of limit
switch function output
state
• Stores output state of limit switch function.
b15
Y0F
b14b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Y0E Y0D Y0C Y0B Y0A Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01 Y00
Axis 1
Axis 2
D9180
Y1F Y1E Y1D Y1C Y1B Y1A Y19 Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y11 Y10
Axis 3
Axis 4
D9181
Y2F Y2E Y2D Y2C Y2B Y2A Y29 Y28 Y27 Y26 Y25 Y24 Y23 Y22 Y21 Y20
Axis 5
Axis 6
D9182
Y3F Y3E Y3D Y3C Y3B Y3A Y39 Y38 Y37 Y36 Y35 Y34 Y33 Y32 Y31 Y30
Axis 7
Axis 8
D9183
"1" is stored in
the bit which
corresponds to
output (Y) which
is turned on. "0"
is stored when
output state is
turned off.
—
Dedicated to
A73.
D9184
Cause of PCPU
error
PCPU error code
• Stores error codes occurred at the PCPU in BIN code.
0: Normal
1: A73CPU hardware error
2: PCPU error
10: A70AF error
11: A70AF error
12: A70MDF error
13: AY42 error
—
Dedicated to
A73.
D9185
Servo amplifier
connection data
Bit pattern of servo
amplifier connection
state
• Servo amplifier connection state is checked and the
result is stored in the bit which corresponds to each axis
number.
Connection state is continuously checked. Axes which
changed from disconnected state to connected state are
regarded as connected. But, axes which changed from
connected state to disconnected state are still regarded
as connected.
b15
b8 b7
b0
0
0
0
0
0
0
0
0
For
axis
8
For
axis
7
For
axis
6
For
axis
5
For
axis
4
For
axis
3
For
axis
2
For
axis
1
All 0
Connected: 1
Disconnected: 0
to
to
—
Dedicated to
A73.
Содержание A1SH
Страница 15: ...MEMO...