APPENDICES
APP - 28
MELSEC-A
Table 2.2
Special registers list (Continue)
Number
Name
Description
Details
Applicable CPU
1
D9100
1
D9101
1
D9102
1
D9103
1
D9104
1
D9105
1
D9106
1
D9107
Fuse blown
module
Bit pattern in units of 16
points of fuse blow
modules
• Output module numbers (in units of 16 points), of which
fuses have blown, are entered in bit pattern. (Preset
output unit numbers when parameter setting has been
performed.)
D9100
D9101
D9107
15 14
12 11
13
10 9 8
6 5 4 3 2 1 0
7
0 0
0
0
0 0 1
(Y80)
0 0 0 0 0 0 0
0
0
0 0
0
1
(Y1A)
0 0
0 0 0 0 0 0 0
0
0 0
0
0
0 0 0
0 0 0
0 0 0
0
Indicates fuse blow.
D9100
D9101
D9107
15 14
12 11
13
10 9 8
6 5 4 3 2 1 0
7
0 0
1
(YC0)
0
0
0 0
0 0 0 0 0 0 0
0
1
(Y1F0)
0
0 0
0
0 0
0 0 0 0 0 0 0
0
0 0
0
0
0 0 0
0 0 0
0 0 0
0
1
Y7
BC
1
1
Y7
30
• Fuse blow check is executed also to the output module of
remote I/O station.
(If normal status is restored, clear is not performed.
Therefore, it is required to perform clear by user
program.)
Usable with all
types of CPUs
Only remote
I/O station
information is
valid for A2C.
1
D9100
Fuse blow
module
Fuse blow module bit
pattern
• Stores the output module number of the fuses have
blown in the bit pattern.
0
0
b15
D9100
b8 b7 b6 b5 b4 b3 b2 b1
0 is fixed.
Indicates the module
for setting switch 0.
Indicates the module
for setting switch 1.
Indicates the module
for setting switch 2.
Indicates the module
for setting switch 3.
Indicates the module for setting
switch 4 or the module for
extension base unit slot 0.
Indicates the module for setting
switch 5 or the module for
extension base unit slot 1.
Indicates the module for setting
switch 6 or the module for
extension base unit slot 2.
Indicates the module for setting switch 7 or
the module for extension base unit slot 3.
b0
—
Dedicated to
A0J2H.
2
D9108
2
D9109
2
D9110
2
D9111
2
D9112
2
D9113
2
D9114
Step transfer
monitoring timer
setting
Timer setting value and
the F number at time
out
• Sets value for the step transfer monitoring timer and the
number of F which turns on when the monitoring timer
timed out.
b15 to b8 b7 to b0
Timer setting
(1 to 255 sec
in seconds)
F number setting
(By turning on any of M9108 to M9114, the monitoring
timer starts. If the transfer condition following a step
which corresponds to the timer is not established within
set time, set annunciator (F) is tuned on.
—
Usable with AnN
, AnA, AnU,
A2AS, AnA
board, QCPU-A
(A Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
: Usable with AnN and AnA which are compatible with SFC.
For the AnN and AnA which are compatible with SFC, refer to the MELSAP-ll Programming Manual.