- 5.8 -
An error occurs in communication
between I/F board and main
board.
The I/F board is not installed.
HOST I/F Timeout error has
arisen during communication
between the host computer and
interface board.
Initial operation failure of the I/F
board and control board.
Improper operation has been
conducted on the operation panel.
Settings for functions have been
tried to be changed though there
remains received data that has
not yet been printed.
The Xmotor has been overload.
The Ymotor has been overload.
Overcurrent error on the Xmotor
has been detected.
Overcurrent error on the Ymotor
has been detected.
Incorrect height of the capping
station has been detected.
Error message
Cause
Corrective measure
Check the output setting of the host
computer.
Install the I/F board.
Check to be sure that the cable is
securely connected to the host
computer and interface board.
Also, check to ascertain that no
error has arisen on the host
computer side.
Turn off the power to the device
and turn it on after a while. If the
same error message appears again
on the LCD, contact your local
distributor to call for service.
Perform a proper operation.
Print all pieces of received data or
execute the data clear function.
Then, change the settings.
Turn off the power to the device
and turn it on after a while. If the
same error message appears again
on the LCD, contact your local
distributor to call for service.
ERROR 20
I/F BOARD
ERROR 21
I/F NONE
ERROR 23
HOST I / F
ERROR 24
I / F INITIAL
ERROR 30
OPERATION
ERROR 34
DATA REMAIN
ERROR 40
MOTOR X
ERROR 41
MOTOR Y
ERROR 42
X CURRENT
ERROR 43
Y CURRENT
ERROR 45
CAPPING