146
Learning Advanced Features
Advanced Tasks
Description
Ref.
Auto restart
operation
Auto restart configuration is used to automatically restart the
inverter when a trip condition is released, after the inverter stops
operating due to activation of protective devices (fault trips).
p.248
Second motor
operation
Used to switch equipment operation by connecting two motors to
one inverter. Configure and operate the second motor using the
terminal input defined for the second motor operation.
p.251
Commercial power
source switch
operation
Used to switch the power source to the motor from the inverter
output to a commercial power source, or vice versa.
p.253
Cooling fan control
Used to control the cooling fan of the inverter.
p.254
Multi-function
output On/Off
control
Set standard values and turn On/Off the output relays or multi-
function output terminals according to the analog input value.
p.294
Regeneration
prevention for press
operation.
Used during a press operation to avoid motor regeneration, by
increasing the motor operation speed.
p.253
Damper operation
Controls the fan motor optimally when a damper is used in the
system.
p.194
Lubrication
operation
Supplies lubricant to the machinery before starting the inverter and
the mechanical system connected to it.
p.196
Flow compensation
Compensates for pressure loss in a system with long pipelines.
p.194
Energy savings
display
Displays the amount of energy saved by the use of the inverter,
compared to when a commercial power source is used without an
inverter.
p.198
Pump clean
operation
Cleans the pumps by removing the scales or deposits that are
attached to the impeller.
p.200
Inclination setting
for operation and
stop
Sets the initial operating conditions for a pump by adjusting the
acceleration and deceleration times.
p.204
Valve deceleration
time setting
Prevents possible pump damage that may be caused by abrupt
deceleration.
p.206
Load tuning
Creates load-specific curves for light load operations and the pump
clean operation.
p.207
Level detection
Detects and displays the level set by the user.
p.209
Pipe breakage
detection
Detects breakages in the pipeline during a PID operation.
p.213
Motor preheating
Prevents motors and pumps from freezing when they are not
operated.
p.216
Scheduled
operation
Uses the built-in real-time clock (RTC) to operate the inverter
according to the desired time schedule.
p.222
Содержание 6731001500
Страница 1: ......
Страница 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Страница 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Страница 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Страница 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Страница 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Страница 22: ...Preparing the Installation 9 500kW 3 Phase ...
Страница 34: ...21 Installing the Inverter 400 V 220 500kW ...
Страница 37: ...Installing the Inverter 24 3 Remove the keypad from the inverter body 0 75 30kWModels 37 90kWModels ...
Страница 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Страница 66: ...Perform BasicOperations 53 ...
Страница 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Страница 107: ...94 Learning BasicFeatures ...
Страница 129: ...116 Learning BasicFeatures second to 0 01 second will resultin amodified acceleration time of 60 00 seconds ...
Страница 151: ...138 Learning BasicFeatures Group Code Name LCDDisplay ParameterSetting SettingRange Unit frequency ...
Страница 187: ...174 Learning Advanced Features PIDCommandBlock ...
Страница 188: ...175 Learning Advanced Features ...
Страница 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Страница 190: ...177 Learning Advanced Features PIDOutputBlock ...
Страница 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Страница 205: ...192 Learning Advanced Features EPID1Controlblock ...
Страница 206: ...193 Learning Advanced Features EPID2Controlblock ...
Страница 228: ...215 Learning Advanced Features ...
Страница 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Страница 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Страница 363: ...350 Learning Protection Features Fan life examination isonlyfor the reference and cannot be used asan absolute value ...
Страница 404: ...391 RS 485 Communication Features B3 4th motor running B2 3rd motor running B1 2nd motor running B0 1st motor running ...
Страница 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Страница 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Страница 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Страница 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Страница 588: ...575 Troubleshooting ...
Страница 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Страница 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Страница 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Страница 643: ...630 ...
Страница 644: ...631 ...
Страница 645: ...632 ...