Learning Advanced Features
5.44.3 Auto Change
The auto change function enables the inverter to automatically switch operations between
main and auxiliary motors. Prolonged continuous operation of a motor deteriorates motor
capabilities. The auto change function switches the motors automatically when certain
conditions are met to avoid biased use of certain motors and protect them from
deterioration.
Group Code Name
LCD Display
Parameter Setting Setting Range
Unit
AP1
55
Auto change
mode selection
Auto Ch Mode
0 None
0 None
-
1 Aux motor
1
AUX
Exchange
2 Main motor
2
Main
Exchange
56
Auto change time
Auto Ch Mode
Time value within
the range
00: 00
–99: 00 Sec.
57
Auto change
frequency
Auto Ch Level
Frequency value
within the range
Low Freq
–
High Freq
Hz
58
Auto change
operation time
Auto Op Time
Time value within
the range
-
Sec.
Auto Change Setting Details
Code
Description
AP1-55 Auto Ch Mode
Select the motors to apply the auto change function.
Setting Description
0
None
1
Aux Exchange
2
Main Exchange
Refer to Examples of Auto Change Sequences below for details.
AP1-56 Auto Ch Time
Sets the auto change intervals.
AP1-57 Auto Ch Level
The parameter is for Main Exchange. In case that [AP1-55 Auto Ch
Mode] is set to Main Exchange, all the conditions for Auto Change
are met under the frequency in which output frequency of Main
motors are set in AP1-57. AP1-57 is the frequency to activate Auto
Change.
Содержание LSLV-H100 Series
Страница 17: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 18: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Страница 19: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Страница 20: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Страница 21: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Страница 22: ...Preparing the Installation 9 500 kW 3 Phase ...
Страница 35: ...Installing the Inverter 22 ...
Страница 50: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Страница 104: ...91 Learning Basic Features 0 10 V Input Voltage Setting Details V1 Quantizing ...
Страница 181: ...168 Learning Advanced Features PID Command Block ...
Страница 182: ...169 Learning Advanced Features ...
Страница 183: ...170 Learning Advanced Features PID Feedback Block ...
Страница 184: ...171 Learning Advanced Features PID Output Block ...
Страница 185: ...172 Learning Advanced Features PID Output Mode Block ...
Страница 198: ...185 Learning Advanced Features EPID1 Control block ...
Страница 199: ...186 Learning Advanced Features EPID2 Control block ...
Страница 220: ...207 Learning Advanced Features ...
Страница 235: ...222 Learning Advanced Features The Time Chart for the Exception Day ...
Страница 506: ...Table of Functions 493 ...
Страница 520: ...Table of Functions 507 8 16 4 Cooling Tower MC4 Group ...
Страница 549: ...Troubleshooting 536 ...
Страница 569: ...Technical Specification 556 11 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 570: ...Technical Specification 557 110 185 kW 3 phase ...
Страница 601: ...588 ...
Страница 602: ...589 ...
Страница 603: ...590 ...