Chapter 2: Installation
Installing the DALLIS Unit(s)
Equipping the 3RU Frame
18 single width DALLIS I/O card slots are available within the
frame. Double width I/O cards (8GU) occupy
two slots; single width I/O cards (4GU) occupy one slot.
·
Slot M1
– fit the main master board here.
·
Slot M2
– reserved for a redundant master board.
·
Slots 1-18
– available for I/O cards.
See
Note that the DALLIS will only work once slot M1 is fitted with a master board. When fitting a redundant master
board, it must be of the same type fitted to slot M1.
Note that the
counts slots from 0 upwards (e.g. physical slot 1 = slot 0 in the logfile).
Not every interface card can be used in every slot. As a general rule, if an interface card is permitted within
, then it can be fitted to your system. Please also refer to the
The type of DALLIS master board, and hence the
, determines the maximum number of audio
channels to/from the Nova: up to 60 (MADI) or 128 (RAVENNA).