mc²56 MKII Technical Manual
V5.10.2/1
285
Chapter 4: Service/Maintenance
Control Surface
5.
Now
the TFT display within the PSU bay. If you lay the display on top of the control surface
panel, you will not need to disconnect any cables.
You will see the power supply block mounted at the rear of the frame:
6.
Using a 7mm hex socket, remove the two screws holding the power supply block in place, followed by
the single screw attaching the protective earth:
Warning
Take care
NOT
to drop any nuts or washers into the desk.
7.
Remove the PSU block from the frame, taking care to extract the distribution and protective earth cables
along with the unit.
8.
Now fit the replacement block (which comes with its own 4-wire distribution and protective earth cabling).
The 4-wire distribution cables should be fed down the distribution board area.
9.
Screw the protective earth to the frame, and replace the two securing screws (see step 6).
10.
Then replace the TFT display (see step 5).
11.
the control surface panel once more, and connect the PSU block to the distribution board (see step
3).
12.
Replace the control surface panel, and fasten into place.
13.
When everything is back in place, re-connect the rear
IEC power connectors, and power on.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...