Chapter 2: Installation
System Settings
The active sync source is selected automatically as follows:
Multichannel
-
Sync Port 1
-
Sync Port 2
-
Internal
. In each case, the status of the sync source and the
Ignore ...
check boxes are taken into account.
For example, with a valid sync signal connected to all inputs and no
Ignore ...
check boxes selected, the system
will lock to the
Multichannel
sync port. If multichannel sync is lost or the signal is invalid, then the system
automatically switches to
Sync Port 1
. Similarly, if sync is lost on this port, then the system switches to
Sync
Port 2
. Finally, if sync is lost on all external ports, then the system switches to
Internal
. An automatic return
mode means that the system will switch back to
Sync Port 2
,
1
or
Multichannel
once a valid signal is detected.
To ignore an external sync source, enable its
Ignore ...
check box. For example, to skip the multichannel sync
source in the sequence, enable the
Ignore Multichannel Input
check box.
If the
Error if Internal Sync
check box is enabled, then an alarm will be triggered when the system switches to
internal sync. The alarm triggers the on-screen
and illuminates the red LED on the front panel of the
Nova73 Router Module.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...