Chapter 5: mcx System Update
Updating the System
·
Insert the new cards. Please take care when inserting the cards to the corresponding card slots. They will
only fit in one direction. Do not force them in, they should fit smoothly.
·
When all cards are installed, the Router Modules MKII can be re-inserted into the Nova73 frame.
·
[mc² series only]
Power down the console control surface.
·
Power up the Nova73 frame.
·
[mc² series only]
Power up the console control surface.
·
The system will cold-start and load a default user configuration. The user data must be restored from the
backup to establish normal system operation (see below).
·
[mc² series only] [optional]
When updating from older versions, sometimes the bayservers need an
update of the bootloader. A special information screen will appear during the boot-up is this is required.
Please follow the instructions on the screen.
·
[mc² series only] [optional]
The console control surface will check for new fader software at the end of
the boot-up. If a change applies, then the software update starts automatically. During this procedure, the
faders and joysticks will move to check the physical boundaries. Please do not obstruct the movement or
touch the faders and joysticks during the calibration.
·
Restore your user data, either by using mxUpdater (via a correctly installed version of mxGUI) or FTP
client. The procedure is similar to the backup described
, except for the direction of transfer.
·
To read the new configuration (loaded from the user data restore), you must perform another cold start.
Please use mxGUI to set the Prepare Coldstart option in the
System Settings
display. Or, use the
Prepare Coldstart
button on the
of the Router Module (MKII). Then switch the Nova73 frame off and
on.
·
As soon as the system has restarted and the configuration has been read correctly, please continue with
the
A telnet or ssh session to the control system can also be used to force a system cold-start: open a telnet or
ssh session to the control system IP address, and login with the username
root
and password
hong
. In the
command line interface, enter
startSystemCold
.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...