Chapter 1: Technical Overview
Redundancy
Control System
The control system resides on the Router Module MKII (980/33).
It runs on an embedded Linux operating system for speed and increased
reliability, and stores both the application software and user data.
The Router Module MKII (980/33) contains a backup power unit
which provides up to 3 seconds of backup power to deal with short
interruptions to mains (AC) power.
Warm Start & Cold Start
Following switch-off, power is provided to the control system for a further 18 seconds. During this time, all current
settings are saved to flash memory; this is known as the system's warm start data.
By default, the warm start data is loaded at the end of boot-up. This means that the console comes back exactly
as it was when you last shut down, ensuring fast recovery of all previous settings following a loss of power.
Alternatively, you can perform a
if you suspect a problem with the warm start data.
Data Recovery
Two flash cards are used to store the application software (
System Flashcard
) and user data (
Data Flashcard
)
separately. You can create a
of the flashcards so that they can be replaced if necessary.
During operation, any errors generated by the control system are stored in the
message
. This can be
copied to USB via the File display, or monitored remotely via the
.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...