mc²56 MKII Technical Manual
V5.10.2/1
56
Chapter 2: Installation
Installing the Control Surface
Ambient Conditions/Air Conditioning
Proper operation of the control surface can only be guaranteed at an ambient temperature between 10° C and 35°
C and a relative humidity between 15% and 85% (not condensing).
To keep the control surface cool in extreme environments, the front panel is fitted with low noise fans. A sensor
within the console activates the cooling fans if the temperature rises above 30° C.
At temperatures below 30° C the cooling fans are switched off permitting installation within noise critical
environments. When relying on convection cooling, ensure that the unit’s ventilation holes are not blocked to allow
air circulation.
Warning
ALWAYS
observe the
around the console frame to allow for ventilation and cable
ducting.
Take care that no devices or cables obstruct the flow of air thereby hindering cooling.