Chapter 2: Installation
Installing the Nova73
Grounding
Although operator protection is guaranteed (the Nova73 is connected via the IEC Power Connectors to the ground
of the power supply system) it is best to establish an additional ground for EMC reasons.
1.
Fasten the grounding cable to the
CASE
grounding bolt (M4 x 8) on the Nova73 rear panel using a Torx
driver:
Warning
The Nova73 must be on the same potential as all other system devices/modules.
For Scandinavian countries,
ALWAYS
use a grounded mains connection, to prevent the device from being
grounded through Ethernet or other signal connections.
Grounding of Audio Interfaces
For compliance with AES3, digital interfaces should be connected to a field ground.