Chapter 2: Installation
Installing the DALLIS Unit(s)
Grounding
Although operator protection is guaranteed (the DALLIS is connected via the IEC Power Connectors to the ground
of the power supply system) it is best to establish an additional ground for EMC reasons.
1.
Fasten the grounding cable to the
M4 CASE
grounding bolt on the rear panel:
Warning
The DALLIS must be on the same potential as all other system devices/modules.
For Scandinavian countries,
ALWAYS
use a grounded mains connection, to prevent the device from being
grounded through Ethernet or other signal connections.
Grounding of Audio Interfaces
For compliance with AES3, digital interfaces should be connected to a field ground.
For connecting microphones, guide the ground connection from the DALLIS to the microphone directly via the
cable shielding, otherwise phantom power cannot be transferred. Take care that the shielding does not lie on the
field ground. This way you will prevent interference and loss of signal quality.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...