Diagnosing System Errors
In the event of a component failure, a hazard warning flag appears in the title bar of the console GUI. Hover over
the warning triangle to view the last ten alarm messages. Messages in red indicate active alarms; messages in
yellow are resolved.
To interrogate further:
1.
Press the
SIGNAL
button, located on the SCREEN CONTROL panel, to view the
Signal Settings
display.
A red/white cross in the
System
tree, and a red highlighted card, show the location the problem.
2.
If the fault is hidden within the
System
tree, follow the red warning flags and open each branch of the tree
to find the problem – in our example, a DALLIS card.
3.
Open the DALLIS card further, and you will see grey/white crosses beside
Signal In 1
,
Signal In 2
, etc.
These show that the AES signals are no longer available:
3.
Check and replace the card if necessary.
Once all components are connected and work ing correctly, the red/white crosses disappear from the
System
Settings
display and the hazard warning flag in the title bar is cleared.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...